MEG VS EEG
Today’s MEG commercial systems are organized in whole-head sensor arrays arranged in a rigid helmet covering most of the head surface but the face area. MEG signals are recorded from about 300 channels, which sometimes consist of pairs of magnetometers to form physical gradiometers (Hämäläinen, Hari, Ilmoniemi, Knuutila, & Lounasmaa, 1993). These latter are less sensitive to far-field sources, which are supposed to originate from distant generators (e.g., road traffic, elevators, heartbeats). An important benefit of MEG systems is the possibility to record EEG from dense arrays of electrodes (>60) simultaneously, thereby completing the electromagnetic signature of neural currents.
Additional analog channels are usually available for miscellaneous recordings (heart monitoring (ECG), muscle activity (EMG), eye movements (EOG), respiration, skin conductance, subject’s responses, etc.). Sampling rate can reach up to 5KHz on all channels with a typical instrumental noise level limited to a few fT/sqrt(Hz). One femto-Tesla (1fT) is 10-15T. Ongoing brain signals measured with MEG are on the range of about [10,50] fT/sqrt(Hz), with a relatively rapid decay in amplitude as frequency increases.
Installation of new MEG systems is presently steadily growing within research and clinical centers (about 200 worldwide).
On the benefits of a larger number of sensors: (a) 3D rendering of a subject’s scalp surface with crosshair markers representing the locations of 151 axial gradiometers as MEG sensors (coil locations are from the VSM MedTech 151 Omega System). (b) Interpolated field topography onto the scalp surface 50 ms following the electric stimulation of the right index finger. The fields reveal a strong and focal dipolar structure above the contralateral central cortex. (c) The number of channels has been evenly reduced to 27. Though the dipolar pattern is still detected, its spatial extension is more smeared – hence the intrinsic spatial resolution of the measurements has been degraded – due to the effect of interpolation between sensors, which are now quite distant from the maxima of the evoked magnetic field pattern.
Basics of EEG and MEG: Physiology and data analysis
Electroencephalography (EEG) is a non-invasive test for epilepsy during which several electrodes are placed on a patient's scalp to record electrical impulses from the brain (brain waves). It is sometimes called a brain wave test, used for testing patients with epilepsy, a brain tumor, a brain abscess, brain trauma, subdural hematoma, meningitis, encephalitis, stroke or congenital defects of the brain.
It is performed by using a device that measures the fluctuations and patterns in electrical processes within the brain.
It is primarily used in medical imaging to visualise the structure and function of the body. It provides detailed images of the body in any plane.
MRI may detect certain lesions (diseased tissue) in the brain that cause seizures. MRI also helps specialists diagnose the causes of epilepsy and evaluate potential candidates for surgery.
Brain abnormalities may be subtle. Specialized MRI scanning may detect asymmetries (dissimilar corresponding parts on opposite sides that are normally alike) in the brain that indicate the side of the brain where seizures begin.
FMRI:
Functional magnetic resonance imaging: a form of magnetic resonance imaging of the brain that registers blood flow to functioning areas of the brain.
It is a relatively new MRI technique that studies brain function. Using fMRI technology, scientists can determine which part of the central nervous system (CNS: brain and spinal cord) is active during a given task by tracking blood oxygen levels in the brain. Brain regions that are active require more oxygen. Oxygen is delivered by increasing the blood flow to these active brain regions. Scientists compare the differences in blood flow between a resting condition and an active condition, such as thinking, seeing, touching, or hearing, to find regions that are associated with one task and not the other.
PET:
Positron emission tomography (PET) is a nuclear medicine imaging technique which produces a three-dimensional image or picture of functional processes in the body. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule. Images of tracer concentration in 3-dimensional or 4-dimensional space (the 4th dimension being time) within the body are then reconstructed by computer analysis. In modern scanners, this reconstruction is often accomplished with the aid of a CT X-ray scan performed on the patient during the same session, in the same machine.
A PET scan analyzes the amount of glucose, or sugar uptake by the brain. One would inject in a glucose substitute that has a label on it, and then take images of the brain during a period of time shortly after the seizure. The PET scan allows us to look at regions of the brain that are either hypermetabolic i.e. using a lot of sugar, or parts of the brain that are hypometabolic i.e. using very little sugar. It turns out that for Temporal Lobe Epilepsy, the temporal lobe shows hypometabolism.
EEG vs fMRI and PET:
EEG has several strong points as a tool for exploring brain activity. EEG's can detect changes within a millisecond timeframe, excellent considering an action potential takes approximately 0.5-130 milliseconds to propagate across a single neuron, depending on the type of neuron. Other methods of looking at brain activity, such as PET and fMRI have time resolution between seconds and minutes. EEG measures the brain's electrical activity directly, while other methods record changes in blood flow (e.g., SPECT, fMRI) or metabolic activity (e.g., PET), which are indirect markers of brain electrical activity. EEG can be used simultaneously with fMRI so that high-temporal-resolution data can be recorded at the same time as high-spatial-resolution data, however, since the data derived from each occurs over a different time course, the data sets do not necessarily represent the exact same brain activity. There are technical difficulties associated with combining these two modalities, including the need to remove the MRI gradient artifact present during MRI acquisition and the ballistocardiographic artifact (resulting from the pulsatile motion of blood and tissue) from the EEG. Furthermore, currents can be induced in moving EEG electrode wires due to the magnetic field of the MRI
Today’s MEG commercial systems are organized in whole-head sensor arrays arranged in a rigid helmet covering most of the head surface but the face area. MEG signals are recorded from about 300 channels, which sometimes consist of pairs of magnetometers to form physical gradiometers (Hämäläinen, Hari, Ilmoniemi, Knuutila, & Lounasmaa, 1993). These latter are less sensitive to far-field sources, which are supposed to originate from distant generators (e.g., road traffic, elevators, heartbeats). An important benefit of MEG systems is the possibility to record EEG from dense arrays of electrodes (>60) simultaneously, thereby completing the electromagnetic signature of neural currents.
Additional analog channels are usually available for miscellaneous recordings (heart monitoring (ECG), muscle activity (EMG), eye movements (EOG), respiration, skin conductance, subject’s responses, etc.). Sampling rate can reach up to 5KHz on all channels with a typical instrumental noise level limited to a few fT/sqrt(Hz). One femto-Tesla (1fT) is 10-15T. Ongoing brain signals measured with MEG are on the range of about [10,50] fT/sqrt(Hz), with a relatively rapid decay in amplitude as frequency increases.
MEG has substantial benefits with respect to EEG:
- while EEG is strongly degraded by the heterogeneity in conductivity within head tissues (e.g., insulating skull vs. conducting scalp), this effect is extremely limited in MEG, resulting in greater spatial discrimination of neural contributions. This has important implications for source modeling as we shall see below;
- Subject preparation time is reduced considerably;
- Measures are absolute, i.e. they are not dependent on the choice of a reference;
- Subject’s comfort is improved as there is no direct contact of the sensors on the skin.
Installation of new MEG systems is presently steadily growing within research and clinical centers (about 200 worldwide).
On the benefits of a larger number of sensors: (a) 3D rendering of a subject’s scalp surface with crosshair markers representing the locations of 151 axial gradiometers as MEG sensors (coil locations are from the VSM MedTech 151 Omega System). (b) Interpolated field topography onto the scalp surface 50 ms following the electric stimulation of the right index finger. The fields reveal a strong and focal dipolar structure above the contralateral central cortex. (c) The number of channels has been evenly reduced to 27. Though the dipolar pattern is still detected, its spatial extension is more smeared – hence the intrinsic spatial resolution of the measurements has been degraded – due to the effect of interpolation between sensors, which are now quite distant from the maxima of the evoked magnetic field pattern.
Introduction to EEG and MEG
Basics of EEG and MEG: Physiology and data analysis
1. Introduction
The
electrical activity of active nerve cells in the brain produces
currents spreading through the head. These currents also reach the scalp
surface, and resulting voltage differences on the scalp can be recorded
as the electroencephalogram (EEG). The currents inside the head produce
magnetic fields which can be measured above the scalp surface as the
magnetoencephalogram (MEG). EEG and MEG reflect brain electrical
activity with millisecond temporal resolution, and are the most direct
correlate of on-line brain processing obtainable non-invasively.
Unfortunately, the spatial resolution of these methods is limited for
principal physical reasons. Even with an infinite amount of EEG and MEG
recordings around the head, a non-ambiguous localisation of the activity
inside the brain would not be possible. This "inverse problem" is
comparable to reconstructing an object from its shadow: only some
features (the shape) are uniquely determined, others have to be deduced
on the ground of additional information. However, by imposing reasonable
modelling constraints or by focussing on rough features of the activity
distribution, useful inferences about the activity of interest can be
made.
The
continuous or spontaneous EEG (i.e. the signal which can be viewed
directly during the recording) can be helpful in clinical environments,
e.g. for diagnosing epilepsy or tumours, predicting epileptic seizures,
detecting abnormal brain states or classifying sleep stages. The
investigation of more specific perceptual or cognitive processes
requires more sophisticated data processing, like averaging the signal
over many trials. The resulting "event-related potentials" or
"event-related magnetic fields" are characterised by a series of
deflections or "components" in their time course, which are
differentially pronounced at different recording sites on the head. They
are classically labelled according to their polarity
(positive/negative) at specific recording sites and the typical latency
of their occurrence (e.g. N100 refers to a negative potential around
100ms, similarly for P300, N400 etc.). The
amplitude and pattern of these components can be interpreted as
dependent variables, which are distinguished by their dependency on the
task, stimulus parameters, degree of attention etc.. Components related
to basic perceptual processing (somato-sensory, visual, auditory, which
are also termed "evoked potentials" or "evoked magnetic fields") can be
used by clinicians to check the connection of the periphery to the
cortex, or can assist in the diagnosis of brain death. Event-related
potentials and magnetic fields are widely used to characterise the
spatio-temporal pattern of brain activity in basically all areas of
neuroscience. Latest developments include the combination of EEG/MEG
with functional magnetic resonance imaging, for combining the superior
spatial resolution of the latter with the better temporal resolution of
the former.
2. Generation of the signals
If
an electrical signal is transmitted along an axon or dendrite,
electrical charges are separated along very short distances on the
corresponding cell membranes. Separated charges act as a small temporary
"battery", with positive polarity at the side where the current is
leaving and with negative polarity where the current is returning. These
"batteries" are called "primary currents" since they are the sources of
interest that reflect directly the activity of the corresponding
neurons. The primary currents are embedded in a conductive medium, i.e.
the brain tissue and brain liquor. Therefore a current is induced which
flows through these media, as well as the skull and scalp, called
"secondary" or "volume" currents. EEG would not be possible without
volume currents, which also reach the scalp surface and cause voltage
differences at the scalp that can be picked up by EEG electrodes. Both
primary and volume currents produce magnetic fields, which sum up and
can be measured by pick-up coils above the head using MEG.
Possible
contributors to the measurable signals are: 1) Action potentials along
the axons connecting neurons, 2) currents through the synaptic clefts
connecting axons with neurons/dendrites, and 3) currents along dendrites
from synapses to the soma of neurons. Action potentials are
"quadrupolar", i.e. two opposing currents occur in vicinity of each
other, the effects of which cancel each other out. In addition, action
potentials last only a few milliseconds, making it more difficult to
achieve a larger number of them being active simultaneously and to sum
up to a measurable signal at larger distance. Synapses are very small
and the current flow relatively slow. Furthermore, they can be located
nearly randomly around a neuron and its dendrites, so that the
contributions of different synapses are likely to cancel each other out.
The current flow along post-synaptical dendrites is dipolar, and at
least the apical dendrites in cortical pyramidal cells are generally
parallely organised. They are typically active for about 10ms after
synaptic input. For these reasons, the apical dendrites of the cortex
are assumed to contribute strongest to the measurable EEG and MEG
signals. Because this activity
directly reflects processing of specific neurons, EEG and MEG are the
most direct correlate of on-line brain processing obtainable
non-invasively. However, one dendrite would be far too weak to produce a
measurable signal, instead tens of thousands are required to be active
synchronously. Consequently, EEG/MEG are only sensitive to coherent
simultaneous activity of a large number of neurons. For modelling
purposes it is important to note that many weak neighbouring dipolar
sources can be summarised to one "dipole", which can be interpreted as a
"piece of active cortex".
3. General data analysis
Sampling Recordings
are taken virtually simultaneously at all recording sites at different
time points. The time difference between sampling points is called the
sampling interval. The sampling rate in Hertz (Hz) is given by the
number of samples per second, i.e. (1000ms/{sampling interval in ms}).
Typical sample intervals are of the order of several milliseconds,
depending on the purpose of the study. If very short-lived brain
processes are of interest, i.e. if the signal is to contain high
frequency components, a higher sampling rate is required (for early
somato-sensory or brain stem potentials, for example, a sampling rate of
about 1000Hz or more is required). This, however, also means more data,
i.e. more storage space is required and further processing will be
slowed down. If slower brain processes are studied and only low
frequency components are of interest, the sampling rate can be reduced
(e.g. about 40Hz for slow waves like the readiness potential). In
typical event-related potential or field studies, where the interesting
frequencies usually lie between 0-100 Hz, a sampling rate of 200-500 Hz
is common. With modern analysis equipment, the computing power and
storage space is usually not a crucial issue any more.
Filtering If
the signal of interest (e.g. a specific ERP component) is already
roughly known, filters can be applied that suppress noise in frequency
ranges where the signal has low amplitude. High-pass filters attenuate
frequencies below a certain cut-off frequency (i.e. they "let pass"
frequencies above it), while low-pass filters behave the other way
round. A combination of a low-pass and a high-pass filter is called a
band-pass filter. A typical band-pass filter for ERP studies would be
0.1-30Hz, but this highly depends on the signal of interest and the
purpose of the study.
Averaging The
brain response of a single event (i.e. the signal after the
presentation of a single stimulus) is usually too weak to be detectable.
The technique usually employed to cope with this problem is to average
over many similar trials. The brain response following a certain
stimulus in a certain task is assumed to be the same or at least very
similar from trial to trial. That means the assumption is made that the
brain response does not considerably change its timing or spatial
distribution during the experiment. The data are therefore divided in
time segments (or "bins") of a fixed length (e.g. one second) where the
time point zero is defined as the onset of the stimulus, for example.
These time segments can then be averaged together, either across all
stimuli present in the study, or for sub-groups of stimuli that shall be
compared to each other. Doing so, any random fluctuations will cancel
each other out, since they might be positive in one segment, but
negative in another. In contrast, any brain response time-locked to the
presentation of the stimulus will add up constructively, and finally be
visible in the average. The
noise level is typically about 20uV, and the signal of interest about
5uV. If the noise was completely random, to reduce the amplitude of the
noise by a factor of n one would have to average across n*n samples.
Averaging over 100 segments would therefore reduce the noise level to
about 2uV, at least less than half the amplitude of the signal of
interest. A further 100 segments (i.e. 200 segments altogether) would
reduce the noise level to about 1.4uV. To reduce the noise level
achieved by 100 segments by a factor 2, one would need 400 segments
(20uV/20=1uV), i.e. 4 times as many. The fact that the noise level in
the average data decreases only with the square root of the number of
trials poses a considerable limitation on the duration of an experiment,
and should be carefully considered prior to setting up a study.
Baseline correction During
the recording, EEG and MEG signals are undergoing slow shifts over
time, such that the zero level might differ considerably across
channels, though the smaller and faster signal fluctuation are similar.
These signal shifts can be due to brain activity, but can also be caused
by sweating (in the case of EEG), muscle tension, or other noise
sources. It would therefore be desirable to have a time range where one
can reasonably assume that the brain is not producing any stimulus
related activity, and that any shift from the zero line is likely due to
noise. In most ERP and ERF studies, this "baseline interval" is defined
as several tens or hundreds of milliseconds preceding the stimulus. For
each recording channel, the mean signal over this interval is computed,
and subtracted from the signal at all time points. This procedure is
usually referred to as "baseline correction". It is crucial in ERP and
ERP experiments to ensure that an observed effect (e.g. an amplitude
difference between the components evoked by two sorts of stimuli) is not
already present in the signal before the stimuli were actually present.
If this was the case, it would indicate that the signal is contaminated
by a confound that is not stimulus-related.
Display In
usual displays for time courses of EEG and MEG data, time is chosen as
the x-axis and the amplitude as the y-axis. Traditionally, negative
amplitudes are often (but not consistently) plotted upwards for EEG
data. If multi-channel ERP and ERF recordings are presented, it is usual
to project the recordings sites on a two-dimensional surface, and to
plot the curves for these recording sites at the corresponding location.
This gives a rough impression of the spatial distribution of the signal
over time. However, with increasing number of recording channels, these
images become very difficult to interpret. If
the spatial distribution of a specific time point or time range (e.g. a
peak) in the signal shall be analysed in more detail, the signal can be
interpolated between recording sites and plotted as a colour-coded map.
Often positive amplitudes are displayed in red colour, and negative
amplitudes by blue colour.
4. EEG recordings
Referencing Electric
potentials are only defined with respect to a reference, i.e. an
arbitrarily chosen "zero level". The choice of the reference may differ
depending on the purpose of the recording. This is similar to measures
of height, where the zero level can be at sea level for the height of
mountains, or at ground level for the height of a building, for example.
For each EEG recording, a
"reference electrode" has to be selected in advance. Ideally, this
electrode would be affected by global voltage changes in the same manner
as all the other electrodes, such that brain unspecific activity is
subtracted out by the referencing (e.g. slow voltage shifts due to
sweating). Also, the reference should not pick up signals which are not
intended to be recorded, like heart activity, which would be "subtracted
in" by the referencing. In most studies, a reference on the head but at
some distance from the other recording electrodes is chosen. Such a
reference can be the ear-lobes, the nose, or the mastoids (i.e. the bone
behind the ears). With multi-channel recordings (e.g. >32 channels),
it is common to compute the "average reference", i.e. to subtract the
average over all electrodes from each electrodes for each time point.
This distributes the "responsibility" over all electrodes, rather than
assigning it to only one of them. If a single reference electrode was
used during the recording, it is always possible to re-reference the
data to any of the recording electrodes (or combinations of them, like
their average) at a later stage of processing. In some cases "bipolar"
recordings are carried out, where electrode pairs are applied and
referenced against each other for each pair (e.g. left-right symmetrical
electrodes).
Electrode locations To
compare results over different studies, electrode locations must be
standardised. These locations should be easily determinable for
individual subjects. Common is the extended 10/20 system, where
electrode locations are defined with respect to fractions of the
distance between nasion-inion (front-back) and the pre-auricular points
(left-right). Obviously, the relative locations of the electrodes with
respect to specific brain structures can only be estimated very roughly.
If this is a crucial point, electrode locations can be digitised
together with some anatomical landmarks (like the pre-auricular points,
the ear-holes, nasion or inion). These landmarks can also be detected in
individual MRI or CT scans if available. The landmarks of the different
co-ordinate systems (EEG digitisation, MRI/CT scan) can then be
matched, such that both data sets are in the same co-ordinate system.
Another possibility is to digitise a large number of points (at least
several hundreds) evenly distributed over the scalp surface, and match
those to the scalp surface segmented from the individual MRI/CT image.
This makes possible more realistic modelling of the head geometry for
sophisticated source estimation, and furthermore the visualisation of
the results with respect to the individual brain geometry.
Fixation of electrodes Clinical
recordings usually employ only few (1-9) electrodes at positions
standardised for given purposes. Modern ERP studies that intend
topographic analysis often employ 32 to 256 electrodes. If only a few
electrodes are used, these can be glued to the skin by hand, using
electrically conducting glue. With larger numbers of electrodes,
electrodes are commonly mounted on a cap. Contact with the skin has then
to be made by introducing a electrically conducting substance between
skin and electrode. Depending on the device, this can be conducting gel,
glue, or sponges soaked with a saline solution. For special
applications, needle electrodes (subduran) are used. Electrodes can be
of different materials: Tin electrodes are cheap but not recommended at
low frequencies. Ag/AgCl (silver-silver-chloride) electrodes are
suitable for a larger frequency range and most commonly used in
research. Gold and platin electrodes are used for special requirements. The
amplitude of the raw signal that is recorded is of the order of 50 uV,
i.e. about a million times weaker than those by household batteries. It
therefore required special amplifiers that amplify the signal and
convert it to a digital signal that can be stored and processed on a
computer. This has to be accomplished at high sampling rates (several
hundred or thousand recordings a second), and virtually simultaneously
for each recording channel.
5. MEG recordings
SQUIDS The
amplitude of the magnetic fields produced spontaneously by the human
brain are of the order piko-Tesla when recorded, and that of the evoked
responses is around 100fT (i.e. more than one million times smaller than
the earth's magnetic field). These very low field strenghts can be
recorded by so-called "Superconducting Interference Devices" (SQUIDS): A
specially prepared pick-up coil is cooled down to superconductivity by
liquid helium, and exploiting a specific quantum effect the magnetic
flux through the coil is measured.
Influence of coil types The
magnetic field, in contrast to the electric potential, has a direction,
usually illustrated by magnetic field lines. A current flowing along a
straight line produces circular magnetic field lines that are concentric
with respect to the current line. If the thumb of your right hand
points in the direction of the current flow (which is from negative to
positive polarity, or "from minus to plus"), then the remaining fingers
point in the direction of the magnetic field ('right-hand-rule'). The
coils pick up only the strength of the magnetic field in the direction
perpendicular to the coil area. Different
coil configurations are in use: A single coil is called a
'magnetometer'. If the difference between two or more neighbouring coils
is measured, it is called a (first order, second order etc.)
'gradiometer'. Gradiometers have the property to be less sensitive to
sources at larger distances, because those have more similar field
strengths at all coils, which in the difference yields lower values.
This has the advantage that noise sources at larger distances are also
suppressed (like the heart, or electric devices near the recording
system). Because MEG sensors are so very sensitive, they have to be
well-shielded against magnetic noise. The shielding of the laboratory
and the SQUID technology make an MEG device 10 to 100 times more
expensive than an EEG system, and the permanent helium-cooling imposes
considerable maintenance costs.
Insensitivity to radial and deep sources A
special and important feature of MEG is its insensitivity to current
sources which are "radial", i.e. which are directed towards or away from
the scalp (like the top of a cortical gyrus). It mainly "sees"
tangential sources, which are parallel to the scalp. The full
explanation for this characteristic would involve a fair amount of
physics and mathematics, but an idea can given for the following
simplified situation. Imagine
the head was modelled as a sphere, and the recording coil would be
tangentially placed above its surface. A dipole within the sphere
pointing towards the coil would produce a magnetic field parallel to the
coil, which would therefore not be measured. The volume currents, on
the other side, are symmetric with respect to the axis along the dipole
direction. This means that the magnetic field through the coil by the
current on one side of this axis is cancelled by the current on the
other side. Therefore the contribution of the primary current as well as
that of the volume current vanish. More detailed analysis of this
problem shows that the magnetic field of a radial dipole in a spherical
volume conductor generally vanishes at all possible recording sites. A
special case of a radial dipole is a dipole located at the centre of
the sphere: It must necessarily point away from the centre, and is
therefore radial and "invisible" for MEG. Roughly speaking, the nearer a
source is to the centre, "the more radial" it is. This implies that the
deeper a source, the less visible it is for MEG. This seems to be a
disadvantage for the MEG, but turns into an advantage if superficial and
tangential sources are targeted at, since in that case the
corresponding MEG signal is less contaminated by other disturbing
sources.
6. Basic differences between EEG and MEG
Both
EEG and MEG are sensitive to the topography of the brain – the details
of the structure of its surface. The brain surface is quite dramatically
folded, and whether the signal arises in the convex tops of the folds
(gyri) or the concave depths of the folds (sulci) affects sensitivity to
neuronal current sources (dipoles). MEG is particularly insensitive to
radial dipoles, those directed towards or away from the scalp (like at
the top of a gyrus). It mainly 'sees' tangential dipoles, which are
parallel to the scalp. The reason for this is that if the head were a
perfect sphere (a reasonable first approximation for an average head
shape), all magnetic fields resulting from a radial dipole (including
the volume currents) cancel each other out at the surface (a more
detailed explanation would involve a fair amounts of physics). EEG is
sensitive to both radial and tangential dipoles.
A
special case of a radial dipole is a dipole located at the centre of a
sphere: it must necessarily point away from the centre, and is therefore
radial and 'invisible' for MEG. Roughly speaking, the nearer a source
is to the centre, 'the more radial' it is. This implies that the deeper a
source is in the head, the less visible it is for MEG. This seems to be
a disadvantage for MEG, but turns into an advantage if superficial and
tangential sources (e.g. in sulci of the cortex) are targeted, since in
that case the corresponding MEG signal is less contaminated than EEG by
other possibly disturbing sources. Furthermore, it has been shown that
superficial and tangential sources can be localized with more accuracy
than with EEG, particular in somatosensory and some auditory parts of
the brain. MEG has therefore been widely used to study early acoustic
and phonetic processing, and the plasticity of the somatosensory and
auditory system.
The
basics of EEG were invented in the 1920s, mainly with medical
applications in mind. EEG is widely used in clinical diagnostics and
research. The first MEG systems (starting with 1-channel!) appeared in
the late 1960s, and first commercial systems took off in the 1980. The
development was mainly driven by engineers and physicists. This, and
possibly the fact that MEG is much more expensive than EEG, often makes
these two look like very different methods with very different
applications. It is important to keep in mind, however, that both
techniques measure the same type of brain activity from slightly
different angles. As a general rule, EEG "sees more" of the brain, but
is less able to localise this activity. MEG "sees less" of the brain,
but what it sees it can localise better. As we will see below, a
combination of EEG and MEG is superior for localisation than each method
on its own. If localisation is not the main focus of a study, EEG may
often be sufficient, for example in many clinical environments.
7. Evoked and Induced Brain Responses
The
averaging procedure described above assumes that there is something
like the average brain response, i.e. a signal with roughly the same
time course in every epoch for a particular stimulus category. But what
if the timing changes slightly from epoch to epoch? If this jitter
across epochs is small compared to the time-scale of the signal, one
does not have to worry. But what if the signal consists of a rapid
sequence of positive and negative deflections (e.g. an "oscillation")?
Then the jitter may sometimes result in a positive value in some epochs,
and negative values in other epochs. Across epochs, this may average
out to zero. This could be the case with co-called "gamma oscillations" –
a signal in the frequency range above 30 Hz (definitions differ
slightly), which has been associated with complex stimulus processing
such as Gestalt perception. These gamma oscillations may occur
time-locked to a stimulus (e.g. always between 200 and 300 ms after
picture onset). However, the "phase information", i.e. the exact
occurrence in time of maxima and minima of the oscillations, may vary
across epochs. These signals are called "induced", or order to
distinguish them from the above-mentioned "evoked" signals that are both
time- and phase-locked to the stimulus. In order to extract induced
signals from the data, the frequency power spectrum (i.e. the signal
amplitude for different frequency bands) has to be computed for every
epoch separately. The power spectrum only contains information about the
amplitude of the signal for a certain frequency in a certain latency
range, but no phase information. If there are consistent gamma
oscillations between 200 and 300 ms after every picture, the spectral
power in the gamma frequency range should be consistently above baseline
level in the latency range across epochs. This method has been applied
to studies on Gestalt perception, as illustrated in the figure below.
For example, it has been found that gamma band activity is usually
larger when an incomplete but meaningful pattern is perceived, compared
to either non-meaningful or easily recognisable patterns.
8. Statistical analysis
The
statistical analysis of EEG/MEG data is as yet not fully standardised,
and the strategies employed can vary considerably depending on the
hypothesis and purpose underlying the experiment. The most frequent
approach is the "Analysis of Variance" or "ANOVA". The signal amplitudes
for different electrodes, sensors or dipoles are considered as
dependent variables, and extracted for each subject (e.g. like mean
reaction times or error rates per subject in behavioural experiments). Imagine
a so-called oddball experiment, in which subjects are presented with
two different tones: One tone of 600Hz, which occurs 90% of the time,
and another tone of 1000Hz, which occurs only 10% of the time. Subjects
are required to press different buttons in response to the frequent and
rare tones. Does the maximum amplitude of the ERP in a certain time
range change as a function of the probability of the tone? In this case,
one would first have to decide which time range to analyse. In this
kind of oddball experiment, it is known that rare tones produce a
so-called "P300", i.e. a positive deflection of the ERP around
centro-parietal electrode sites, which usually reaches its maximum
around 300ms after stimulus onset. It would therefore be reasonable to
look for the largest peak around 300ms at the electrode Pz, and to
extract the amplitudes at this electrode and this point in time for all
subjects. These values would enter the ANOVA as a dependent variable.
"Probability" would be a single, two-level factor allowing for a
comparison between values obtained for the presentation of the rare
tones with those obtained for the frequent tones. In general, the result
is that the amplitude of the P300 is larger for rare tones. Does
only the amplitude change with the toneâs probability of occurrence, or
could there also be a change of "Laterality"? In other words, could the
rare tones produce larger amplitudes in either the left or right
hemisphere compared with the frequent ones? In this case, one would have
to extract amplitude values for at least two electrodes, one in the
left and one in the right hemisphere (e.g. P5 and P6, left and right of
Pz). The ANOVA now has two factors: Probability (rare and frequent) and
Laterality (left and right). If the laterality changes with tone
probability, one should obtain an interaction between Probability and
Laterality. In the case of simple tones, such an interaction is
generally not found, although it might be expected for more complex
(e.g. language-related) stimuli. If
such a hypothesis-based approach is not suitable (e.g. because there is
no specific hypothesis, or because the hypothesis was falsified but one
still does not want to give up...), exploratory strategies have to be
used. For example, separate statistical tests (like paired T-tests) can
be computed electrode by electrode, or dipole by dipole. However, if we
perform statistical comparisons at different recording sites or source
locations, and each of those by itself has a chance of 5% to produce a
false positive (i.e. tells us there is a significant difference when in
fact there is not), then we have to expect that a fraction of 5% of our
locations are incorrectly labeled as significant. This is the common
problem of multiple comparisons. Methods to deal with this problem in
the case of EEG and MEG data are currently under development.
9. Estimating the neuronal sources
Underdeterminacy of the inverse problem Even
if the EEG and MEG were measured simultaneously at infinitely many
points around the head, the information would still be insufficient to
uniquely compute the distribution of currents within the brain that
generated these signals. The so-called "inverse problem", i.e. the
estimation of the sources given the measured signals, is
"under-determined" or "ill-posed". But
all is not lost: By imposing appropriate modelling constraints, one can
often derive valuable information about spatial features of the source
distribution from the data. The main questions in this context are: Do I
have enough information from other sources (neuropsychology, other
neuro-imaging results) to narrow down the possible generators? Or can I
ask my questions such that it is not necessary to know the exact source
distribution, but only some rough features that can be determined
without further modelling constraints?
Approaches to deal with the inverse problem One
can distinguish between two strategies to tackle the inverse problem:
1) Approaches that make specific modelling assumptions, like the number
of focal sources needed to produce the recorded data and their
approximate location, and 2) approaches that make as little modelling
assumptions as possible, and focus on rough features of the current
distribution that are determined by the data rather than specific
modelling assumptions (like laterality). Under 1) fall the so-called
'dipole models': The number of active dipoles, i.e. small pieces of
activated cortex, is assumed to be known (usually only a few). An
initial guess about their location and orientation is made, and these
parameters are then adjusted step by step until the predicted electric
potential or magnetic field resembles the measured one within certain
limits. These methods have been successfully applied in studies of
perceptual processes and early evoked components. Point
2) comprises the 'distributed source models': The naturally continuous
real source distribution is approximated by a large number (several
hundreds or thousands) of sources equally distributed over the brain.
The strengths of all these sources cannot be estimated independently of
each other, but at least a "blurred" version of the real source
distribution can often be obtained. Peaks in this estimated current
distribution might correspond to centres of activity in the real current
distribution. These methods are preferred if modelling assumptions for
dipole models cannot be justified, like in cognitive tasks or in noisy
data.
10. EEG, MEG and fMRI: Localisation Issues
Although
the signals of EEG and MEG are generated by the same sources
(electrical currents in the brain), they are both sensitive to different
aspects of these sources (as described above). This could be compared
to viewing the shadows of the same object from two different angles. It
should not be surprising then that the information of EEG and MEG are
complementary, and combining the two in source estimation usually yields
more accurate result than using either method alone. However, this also
means more work, and not everybody has both EEG and MEG available. It
is therefore important to decide at the beginning of a study 1) whether
localisation is required at all; 2) whether absolute anatomical
localisation is required (e.g. in combination with structural MRI
images), or whether relative localisation (e.g. "left more than right")
is sufficient; 3) whether it is already known that the sources are
visible in EEG, MEG or both.
While
for EEG and MEG, we can safely assume that we are measuring the same
sources from different angles, the same cannot be said for fMRI compared
to EEG/MEG. Standard fMRI measures a blood-oxygen-level dependent
(BOLD) signal. This is a metabolic (rather than electric) signal,
depending on how much oxygen is consumed in different brain areas. Its
time course after stimulus presentation usually peaks around 5 s, but
can last for up to 30 s. This is a much slower time scale than the
millisecond temporal resolution of EEG and MEG. fMRI data are therefore
usually not presented over time, but as one image that collapses brain
activation over several seconds. There is still no clear model of how
the electrophysiological sources of EEG and MEG relate to the
metabolical fMRI signal. It cannot be generally assumed that activation
hot spots in fMRI are also visible in EEG/MEG, or vice versa. Even if
there is some correspondence, brain areas shown as activated in fMRI
maps may activate at different time points in EEG/MEG. So far, some
successful combinations of EEG/MEG with fMRI have been achieved for
relatively simple perceptual processes. These are usually reflected in
early EEG/MEG signals, and can be localised to a few focal brain areas.
In
the example presented in the figure below, the combination of EEG and
MEG for the estimation of early visually evoked responses is compared to
fMRI data. Simple visual stimuli (socalled Gabor patches) were flashed
in the four quadrants of the visual field (upper left, upper right,
lower left, lower right). It is known that such stimuli activate
characteristic retinotopic areas of limited extent (~ 1 cm2) in visual
cortex in the occipital lobe (cortical area V1). Changing the stimulus
location therefore changes the cortical response location in a
predictable way. For example, visual stimuli presented in the left
visual hemifield activate V1 in the right cortical hemisphere, and vice
versa for right hemifield stimuli. Similarly, stimuli in the upper/lower
visual field activate lower/upper parts of V1. This response pattern
can then be compared across different localisation techniques.
The
expected pattern of activation is clearly present in the fMRI data
presented at the top of the figure below. This technique provides
millimetre spatial resolution, but does not tell us whether this
activation reflects early or late processes. EEG and MEG show a similar
pattern around 74 ms after stimulus onset – this is about the time when
visual information from the retina first reaches visual cortex.
Localisations for EEG and MEG separately show approximately the same
patterns, although EEG alone is quite far off in one case (left panel).
The combination of EEG and MEG, however, nicely resembles the pattern
obtained using fMRI. It confirms that this pattern reflects an early
processing stage in visual cortex.
Note
that the images for fMRI as well EEG/MEG are "tresholded", i.e. only
activations above a certain value are shown. These represent the "tip of
the iceberg", but the true spatial extent of activation can be
difficult to determine. Especially for the case of EEG/MEG one has to
keep in mind that spatial resolution is fundamentally limited, and that
the estimated activations are always more blurred than the true
underlying neural sources. Furthermore, there is no perfect match
between fMRI and EEG/MEG. It is not clear whether this reflects the
resolution limits of these methods, or fundamentally different
physiological sources of the signals (electrical vs. metabolic). For
this simple data set, the correspondence between the imaging techniques
appears to be very high. However, for higher cognitive processes, the
discrepancy may be much larger. A combination of these two imaging
modalities should be considered with great care - an independent
analysis and later comparison of fMRI and EEG/MEG may be more
appropriate.
EEG:
Electroencephalography (EEG) is a non-invasive test for epilepsy during which several electrodes are placed on a patient's scalp to record electrical impulses from the brain (brain waves). It is sometimes called a brain wave test, used for testing patients with epilepsy, a brain tumor, a brain abscess, brain trauma, subdural hematoma, meningitis, encephalitis, stroke or congenital defects of the brain.
It is performed by using a device that measures the fluctuations and patterns in electrical processes within the brain.
MRI:
MRI is a magnetic resonance imaging: the use of
nuclear magnetic resonance of protons to produce proton density images.
It is a type of diagnostic imaging that uses electromagnetic imaging
and allows evaluation of tissues and fluid in addition to bone. This
imaging providing two dimensional cuts through the body part being study
which allows a physician to develop a three dimensional sense of the
anatomy of that part. Often used to study the brain and spine as well as
joints. It is primarily used in medical imaging to visualise the structure and function of the body. It provides detailed images of the body in any plane.
MRI may detect certain lesions (diseased tissue) in the brain that cause seizures. MRI also helps specialists diagnose the causes of epilepsy and evaluate potential candidates for surgery.
Brain abnormalities may be subtle. Specialized MRI scanning may detect asymmetries (dissimilar corresponding parts on opposite sides that are normally alike) in the brain that indicate the side of the brain where seizures begin.
FMRI:
Functional magnetic resonance imaging: a form of magnetic resonance imaging of the brain that registers blood flow to functioning areas of the brain.
It is a relatively new MRI technique that studies brain function. Using fMRI technology, scientists can determine which part of the central nervous system (CNS: brain and spinal cord) is active during a given task by tracking blood oxygen levels in the brain. Brain regions that are active require more oxygen. Oxygen is delivered by increasing the blood flow to these active brain regions. Scientists compare the differences in blood flow between a resting condition and an active condition, such as thinking, seeing, touching, or hearing, to find regions that are associated with one task and not the other.
PET:
Positron emission tomography (PET) is a nuclear medicine imaging technique which produces a three-dimensional image or picture of functional processes in the body. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule. Images of tracer concentration in 3-dimensional or 4-dimensional space (the 4th dimension being time) within the body are then reconstructed by computer analysis. In modern scanners, this reconstruction is often accomplished with the aid of a CT X-ray scan performed on the patient during the same session, in the same machine.
A PET scan analyzes the amount of glucose, or sugar uptake by the brain. One would inject in a glucose substitute that has a label on it, and then take images of the brain during a period of time shortly after the seizure. The PET scan allows us to look at regions of the brain that are either hypermetabolic i.e. using a lot of sugar, or parts of the brain that are hypometabolic i.e. using very little sugar. It turns out that for Temporal Lobe Epilepsy, the temporal lobe shows hypometabolism.
EEG vs fMRI and PET:
EEG has several strong points as a tool for exploring brain activity. EEG's can detect changes within a millisecond timeframe, excellent considering an action potential takes approximately 0.5-130 milliseconds to propagate across a single neuron, depending on the type of neuron. Other methods of looking at brain activity, such as PET and fMRI have time resolution between seconds and minutes. EEG measures the brain's electrical activity directly, while other methods record changes in blood flow (e.g., SPECT, fMRI) or metabolic activity (e.g., PET), which are indirect markers of brain electrical activity. EEG can be used simultaneously with fMRI so that high-temporal-resolution data can be recorded at the same time as high-spatial-resolution data, however, since the data derived from each occurs over a different time course, the data sets do not necessarily represent the exact same brain activity. There are technical difficulties associated with combining these two modalities, including the need to remove the MRI gradient artifact present during MRI acquisition and the ballistocardiographic artifact (resulting from the pulsatile motion of blood and tissue) from the EEG. Furthermore, currents can be induced in moving EEG electrode wires due to the magnetic field of the MRI