Thursday, October 10, 2013

Wi-Vi : See Through Walls with Wi-Fi







leave a comment
Join the blog......and leave the request for full report .
 FOR FULL REPORT CONTACT: archives.biomed@gmail.com
  

 Wi-Vi : See Through Walls with Wi-Fi


Can Wi-Fi signals enable us to see through walls? For many years, humans have fantasized about X-ray vision and played with the concept in comic books and sci-fi movies. This thesis explores the potential of using Wi-Fi signals and recent advances in MIMO communications to build a device that can capture the motion of humans behind a wall and in closed rooms. Law enforcement personnel can use the device to avoid walking into an ambush, and minimize casualties in standoffs and hostage situations. Emergency responders can use it to see through rubble and collapsed structures. Ordinary users can leverage the device for gaming, intrusion detection, privacy-enhanced monitoring of children and elderly, or personal security when stepping into dark alleys and unknown places. 

The concept underlying seeing through opaque obstacles is similar to radar and sonar imaging. Specifically, when faced with a non-metallic wall, a fraction of the RF signal would penetrate the wall, reflect off objects and humans, and come back imprinted with a signature of what is inside a closed room. By capturing these reflections, we can image objects behind a wall. Building a device that can capture such reflections, however, is difficult because the signal power after traversing the wall twice (in and out of the room) is reduced by three to five orders of magnitude. Even more challenging are the reflections from the wall itself, which are much stronger than the reflections from objects inside the room [13, 28]. Reflections off the wall overwhelm the receiver’s analog to digital converter (ADC), preventing it from registering the minute variations due to reflections from objects behind the wall. This behavior is called the “Flash Effect” since it is analogous to how a mirror in front of a camera reflects the camera’s flash and prevents it from capturing objects in the scene. 

So how can one overcome these difficulties? The radar community has been investigating these issues, and has recently introduced a few ultra-wideband systems that can detect humans moving behind a wall, and show them as blobs moving in a dim background [28, 41] (see the video at [6] for a reference). Today’s state-of-the-art system requires 2 GHz of bandwidth, a large power source, and an 8-foot long antenna array (2.4 meters) [12, 28]. Apart from the bulkiness of the device, blasting power in such a wide spectrum is infeasible for entities other than the military. The requirement for multi-GHz transmission is at the heart of how these systems work: 
they separate reflections off the wall from reflections from the objects behind the wall based on their arrival time, and hence need to identify sub-nanosecond delays (i.e., multi-GHz bandwidth) to filter the flash effect.To address these limitations, an initial attempt was made in 2012 to use Wi-Fi to see through a wall. However, to mitigate the flash effect, this past proposal needs to install an additional receiver behind the wall, and connect the receivers behind and in-front of the wall to a joint clock via wires.

Seeing Through Walls with Wi-Fi   


The objective of this thesis is to enable a see-through-wall technology that is low-bandwidth, low-power, compact, and accessible to non-military entities. To this end, the thesis introduces Wi-Vi, a see-through-wall device that employs Wi-Fi signals in the 2.4 GHz ISM band. Wi-Vi limits itself to a 20 MHz-wide Wi-Fi channel, and avoids ultra-wideband solutions used today to address the flash effect. It also disposes of the large antenna array, typical in past systems, and uses instead a smaller  3-antenna MIMO radio. 

So, how does Wi-Vi eliminate the flash effect without using GHz of bandwidth?  We observe that we can adapt recent advances in MIMO communications to through wall imaging. In MIMO, multiple antenna systems can encode their transmissions so that the signal is nulled (i.e., sums up to zero) at a particular receive antenna. 

MIMO systems use this capability to eliminate interference to unwanted receivers. In contrast, we use nulling to eliminate reflections from static objects, including the wall. Specifically, a Wi-Vi device has two transmit antennas and a single receive antenna. Wi-Vi operates in two stages. In the first stage, it measures the channels from each of its two transmit antennas to its receive antenna. In stage 2, the two transmit antennas use the channel measurements from stage 1 to null the signal at the receive antenna.
 

Since wireless signals (including reflections) combine linearly over the medium, only reflections off objects that move between the two stages are captured in stage  2. Reflections off static objects, including the wall, are nulled in this stage. In §4, we refine this basic idea by introducing iterative nulling, which allows us to eliminate residual flash and the weaker reflections from static objects behind the wall. 

Second, how does Wi-Vi track moving objects without an antenna array? To address this challenge, we borrow a technique called inverse synthetic aperture radar (ISAR), which has been used for mapping the surfaces of the Earth and other planets. ISAR uses the movement of the target to emulate an antenna array. As shown in Fig. 1-1, a device using an antenna array would capture a target from spatially spaced antennas and process this information to identify the direction of the target with respect to the array (i.e., θ). In contrast, in ISAR, there is only one receive antenna; hence, at any point in time, we capture a single measurement. Nevertheless, since the target is moving, consecutive measurements in time emulate an inverse antenna array - i.e., it is as if the moving human is imaging the Wi-Vi device. By processing such consecutive measurements using standard antenna array beam steering, Wi-Vi can identify the spatial direction of the human. In §5.2, we extend this method to multiple moving targets. 

Additionally, Wi-Vi leverages its ability to track motion to enable a through-wall gesture-based communication channel. Specifically, a human can communicate messages to a Wi-Vi receiver via gestures without carrying any wireless device. We have picked two simple body gestures to refer to “0” and “1” bits. A human behind a wall may use a short sequence of these gestures to send a message to Wi-Vi. After applying a matched filter, the message signal looks similar to standard BPSK encoding (a positive signal for a “1” bit, and a negative signal for a “0” bit) and can be decoded by considering the sign of the signal. The system enables law enforcement personnel
to communicate with their team across a wall, even if their communication devices are confiscated.

Evaluation of Wi-Vi   

We built a prototype of Wi-Vi using USRP N210 radios and evaluated it in two office buildings. Our results are as follows: 

• Wi-Vi can detect objects and humans moving behind opaque structural obstructions. This applies to 8′′  concrete walls, 6′′  hollow walls, and 1.75′′  solid wooden doors. The video available in [9] shows a demo of how Wi-Vi tracks a moving human from behind a wall.
• A Wi-Vi device pointed at a closed room with  6′′  hollow walls supported by steel frames can distinguish between 0, 1, 2, and 3 moving humans in the room. The precisions with which Wi-Vi identifies each case, computed over 80 trials with 8 human subjects, are 100%, 100%, 85% and 90% respectively.
• In the same room, and given a single person sending gesture-based messages, Wi-Vi correctly decodes all messages performed at distances equal to or smaller than 5 meters. The decoding accuracy decreases to 75% at distances of 8 meters, and the device stops detecting gestures beyond 9 meters. For 8 volunteers who participated in the experiment, on average, it took a person 8.8 seconds to send a message of 4 gestures.
• In comparison to the state-of-the-art ultra-wideband see-through-wall radar [28], Wi-Vi is limited in two ways. First, replacing the antenna array by ISAR means that the angular resolution in Wi-Vi depends on the amount of movement. To achieve a narrow beam, the human needs to move by about 4 wavelengths (i.e., about  50  cm). Second, in contrast to  [28], we cannot detect humans behind concrete walls thicker than  8′′. This is due to both the much lower transmit power from our USRPs and the residual flash power from imperfect nulling. On the other hand, nulling the flash removes the need for GHz bandwidth. It also removes clutter from all static reflectors, rather than just one wall. This includes other walls in the environments as well as furniture inside and outside the imaged room. To reduce clutter, the empirical results in past work are typ-
ically collected using a person-height standing wall, positioned either outdoors
or in large empty indoor spaces  [28,  41]. In contrast, our experiments are in standard office buildings with the imaged humans inside closed fully-furnished rooms.
 

Contributions
In contrast to past work which targets the military, Wi-Vi introduces novel solutions to the see-through-wall problem that enable non-military entities to use this technology. Specifically, Wi-Vi is the first to introduce interference nulling as a mechanism for eliminating the flash effect without requiring wideband spectrum. It is also the first to replace the antenna array at the receiver with an emulated array based on human motion. The combination of those techniques enables small cheap devices that operate in the ISM band, and can be made accessible to the general public. Further, Wi-Vi is the first to demonstrate a gesture-based communication channel that operates through walls and does not require the human to carry any wireless device. 

Related Work

3.2   Device Operation
Wi-Vi can be used in one of two modes, depending on the user’s choice. In mode 1,
it can be used to image moving objects behind a wall and track them. In mode 2, on


Through-wall Radar
Interest in through-wall imaging has been surging for about a decade [5]. Earlier work in this domain focused on simulations [39, 29] and modeling [33, 34]. Recently, there have been some implementations tested with moving humans [28, 41, 14]. These past systems eliminate the flash effect by isolating the signal reflected off the wall from signals reflected off objects behind the wall. This isolation can be achieved in the time domain, by using very short pulses (less than 1ns) [42, 5] whereby the pulse reflected off the wall arrives earlier in time than that reflected off moving objects behind it. Alternatively, it may be achieved in the frequency domain by using a linear frequency chirp  [13,  28]. In this case, reflections off objects at different distances arrive with different tones. By analog filtering the tone that corresponds to the wall, one may remove the flash effect. These techniques require ultra-wide bandwidths (UWB) of the order of 2 GHz [13, 42]. Similarly, through-wall imaging products developed by the industry  [5,  7] hinge on the same radar principles, requiring multiple GHz of bandwidth and hence are targeted solely at the military.
As a through-wall imaging technology, Wi-Vi differs from all the above systems in that it requires only few MHz of bandwidth and operates in the same range as Wi-Fi. It overcomes the need for UWB by leveraging MIMO nulling to remove the flash effect. 

Researchers have recognized the limitations of UWB systems and explored the potential of using narrowband radars for through-wall technologies [30, 31]. These systems ignore the flash effect and try to operate in presence of high interference caused by reflections off the wall. They typically rely on detecting the Doppler shift caused by moving objects behind the wall. However, the flash effect limits their detection capabilities. Hence, most of these systems are demonstrated either in simulation [29], or in free space with no obstruction [22, 24]. The ones demonstrated with an obstruction use a low-attenuation standing wall, and do not work across higher attenuation materials such as solid wood or concrete [30, 31]. Wi-Vi shares the objectives of these devices; however, it introduces a new approach for eliminating the flash effect without wideband transmission. This enables it to work with concrete walls and solid wood doors, as well as fully closed rooms. 

The only attempt which we are aware of that uses Wi-Fi signals in order to see through walls was made in 2012 [14]. This system required both the transmitter and a reference receiver to be inside the imaged room. Furthermore, the reference receiver in the room has to be connected to the same clock as the receiver outside the room. In contrast, Wi-Vi can perform through-wall imaging without access to any device on the other side of the wall.

        Gesture-based Interfaces
Today, commercial gesture-recognition systems - such as the Xbox Kinect [10], Nin- tendo Wii [4], etc. - can identify a wide variety of gestures. The academic community has also developed systems capable of identifying human gestures either by employing cameras [25] or by placing sensors on the human body [16, 21]. Recent work has also leveraged narrowband signals in the 2.4 GHz range to identify human activities within line-of-sight using micro-Doppler signatures [22]. Wi-Vi, however, presents the first gesture-based interface that works in non-line-of-sight scenarios, and even through a wall, yet does not require the human to carry a wireless device or wear a set of sensors.

        Infrared and Thermal Imaging
Similar to Wi-Vi, infrared and thermal imaging technologies extend human vision beyond the visible electromagnetic range, allowing us to detect objects in the dark or in smoke. They operate by capturing infrared or thermal energy reflected off the first obstacle in line-of-sight of their sensors. However, cameras based on these technologies cannot see through walls because they have very short wavelengths (few µm to submm) [38], unlike Wi-Vi which employs signals whose wavelengths are 12.5 cm.

 
Wi-Vi Overview    

Wi-Vi is a wireless device that captures moving objects behind a wall. It leverages the ubiquity of Wi-Fi chipsets to make through-wall imaging relatively low-power, low-cost, low-bandwidth, and accessible to average users. To this end, Wi-Vi uses Wi-Fi OFDM signals in the ISM band (at 2.4 GHz) and typical Wi-Fi hardware. 
         
Device Description 

Wi-Vi is essentially a  3-antenna MIMO device: two of the antennas are used for transmitting and one is used for receiving. It also employs directional antennas to focus the energy toward the wall or room of interest.Its design incorporates two main components: 1) the first component eliminates the flash reflected off the wall by performing MIMO nulling; 2) the second component tracks a moving object by treating the object itself as an antenna array using a technique called inverse SAR. 

        Device Operation
Wi-Vi can be used in one of two modes, depending on the user’s choice. In mode 1, it can be used to image moving objects behind a wall and track them. In mode 2, on the other hand, Wi-Vi functions as a gesture-based interface from behind a wall that enables humans to compose messages and send them to the Wi-Vi receiver. 

Eliminating the Flash

In any through-wall imaging system, the signal reflected off the wall, i.e., the flash, is much stronger than any signal reflected from objects behind the wall. This is due to the significant attenuation which electromagnetic signals suffer when penetrating dense obstacles. Table 4.1 shows a few examples of the one-way attenuation experienced by Wi-Fi signals in common construction materials (based on [1]). For example, a one-way traversal of a standard hollow wall or a concrete wall can reduce Wi-Fi signal power by 9 dB and 18 dB respectively. Since through-wall systems require traversing the obstacle twice, the one-way attenuation doubles, leading to an 18-36 dB flash effect in typical indoor scenarios.
  

This problem is exacerbated by two other parameters: First, the actual reflected signal is significantly weaker since it depends both on the reflection coefficient as well as the cross-section of the object. The wall is typically much larger than the objects of interest, and has a higher reflection coefficient [13]. Second, in addition to the direct flash caused by reflections off the wall, through-wall systems have to eliminate the direct signal from the transmit to the receive antenna, which is significantly larger than the reflections of interest. Wi-Vi uses interference nulling to cancel both the wall reflections as well as the direct signal from the transmit to the receive antenna, hence increasing its sensitivity to the reflections of interest. 

Nulling to Remove the Flash
Recent advances show that MIMO systems can pre-code their transmissions such that
the signal received at a particular antenna is cancelled [37, 18]. Past work on MIMO
has used this property to enable concurrent transmissions and null interference [27,
23]. We observe that the same technique can be tailored to eliminate the flash effect
as well as the direct signal from the transmit to the receive antenna, thereby enabling
Wi-Vi to capture the reflections from objects of interest with minimal interference.
At a high level, Wi-Vi’s nulling procedure can be divided into three phases: initial nulling, power boosting, and iterative nulling, as shown in Alg. 1.

          Initial Nulling
In this phase, Wi-Vi performs standard MIMO nulling. Recall that Wi-Vi has two transmit  antennas and  one  receive  antenna.  First,  the  device  transmits  a  known preamble x only on its first transmit antenna. This preamble is received at the receive antenna as y = h1x , where h1  is the channel between the first transmit antenna and the receive antenna. The receiver uses this signal in order to compute an estimate of the channel hˆ1. Second, the device transmits the same preamble x , this time only on its second antenna, and uses the received signal to estimate channel h2  between thesecond transmit antenna and the receive antenna. Third, Wi-Vi uses these channel estimates to compute the ratio p = −hˆ1/hˆ2. Finally, the two transmit antennas transmit concurrently, where the first antenna transmits x and the second transmits px . Therefore, the perceived channel at the receiver.

Power Boosting
Simply nulling static reflections, however, is not enough because the signals due to
moving objects behind the wall are too weak. Say, for example, the flash effect was 30
to 40 dB above the power of reflections off moving objects.

ACCELEROMETERS


ACCELEROMETERS

1.      INTRODUCTION

Acceleration is the rate of change of either the magnitude or the direction of the velocity of an object, and it is measured in units of length per time squared (i.e., m/s2) or units of gravity (g) (1 g¼9.81 m/s2). Devices that measure acceleration, or accelerometers, are used in high performance devices such as missile guidance systems, airbag deployment systems in automobiles, in handheld electronics, as well as in biomedical applications such as motion analysis or assessment of physical activity.

In the most general terms, an accelerometer consists of a mass, spring, and damper. The acceleration of the mass is measured by the deformation of the spring, and oscillation of the spring is controlled by the damper. The acceleration of the mass should not affect the actual acceleration of the object being monitored, so size is an important design criterion.

The earliest devices that were designed in the 1930s were based on strain gages in a Wheatstone bridge configuration on a small frame supporting a mass weighing over 3 pounds (1). Current accelerometers are typically electronic devices based on piezoelectric or semiconductor technology. Depending on the device and its design, an accelerometer can measure very small accelerations caused by vibration (micro g), or very large accelerations during motion or impact (thousands of g’s).

2. THEORY

Most accelerometers contain a known mass (sometimes referred to as a seismic mass or a proof mass) and some means for measuring either the resultant force or the displacement when the mass is accelerated. These types of accelerometers work by the principle of Newton’s second law of mechanics, which states that the force (F) acting on an object that is accelerating will be proportional to its acceleration (a), and the proportionality constant is the mass (m) of the object: F¼ma.

An example of a simple accelerometer is a mass attached to a spring and ruler, where the deflection of the spring is proportional to the force acting on it. As the force is directly proportional to the acceleration of the mass, acceleration in the direction of the ruler can be calculated by measuring the spring deflection. Most electronic accelerometers use a similar principle, measuring the displacement of the mass in the desired direction and producing an output signal proportional to the acceleration.

Piezoelectric materials, which develop an electric charge when deformed, were used to make some of the first modern accelerometers in the 1940s and 1950s and are the most common and cost-effective types of accelerometers being used today. Such a device is typically comprised of a piezoelectric crystal supporting a small mass. Acceleration produces a force proportional to the mass, which causes a change in the electrical output of the piezoelectric crystal.

Piezoresistive accelerometers measure the force produced by the acceleration of an internal mass by the change in resistance of the material (often silicon based) when a force is applied to it. Recently developed thermal accelerometers do not use amass/spring configuration, but instead sense acceleration by changes in heat transfer between micromachined elements within a small, insulated space.

3. PERFORMANCE

The optimum performance of an accelerometer is based on the linearity of its response, its frequency bandwidth, its sensitivity to acceleration, and minimal cross-sensitivity. All electronic devices have some useable range in which their response is linear (i.e., the electrical output is directly proportional to the parameter being measured).

Mass-spring-damper accelerometers have a natural frequency at which they oscillate that is particular to their design and construction, also called the resonant frequency. The usable frequency range is the flat area of the frequency response curve, which is a plot of the deviation in output versus frequency. Frequencies below about one-third to one-half of the resonant frequency are generally within the range in which the device response is linear,
and this range is referred to as bandwidth (see Fig. 1).

Sensors that can sense constant accelerations are said to have a ‘‘DC response’’ (0 Hz). Those that are functional below several hundred Hz are referred to as ‘‘low frequency’’ sensors. The upper limit of the bandwidth is determined by the physical properties of the device such as the dimensions of the mass and beam, the location of the mass on the beam, and the elastic modulus of the material that it is made from. The lower limit is governed by the amplifier and electronic response of the device. These parameters are all optimized to provide the widest possible bandwidth or range of operation for a specific device.

The sensitivity of the accelerometer is defined as the ratio of the change in output to the relative change in acceleration. As sensitivity is determined by the same physical properties as bandwidth, there is a tradeoff between sensitivity and bandwidth for most devices (except thermal accelerometers). A small mass usually means a lower sensitivity, which is typical for most high-frequency accelerometers. Accelerometers generally have an output that is some voltage that is proportional to acceleration, reported as a ratio of the output to input. Output units are typically mV/V/G. As the output is dependent on the input, or excitation voltage, care must be taken to provide a properly regulated input voltage.

Accelerometers are designed to be sensitive to accelerations only in a specified direction. However, the accelerometer will also sense accelerations in other directions to a certain degree, which is called cross-sensitivity or transverse sensitivity, which can contribute to errors in measurement and is usually quantified and reported by device manufacturers. All devices have some sensitivity to fluctuations in temperature that may affect their performance, which is also reported by the manufacturer, and the thermal environment should be taken into consideration when choosing a device for a particular application.

Electronic devices can be damaged by overloading or by accelerating it beyond its normal range of operation. Some devices have overload protection built in to their design, which will protect against accelerations during typical handling. However, a trade-off exists between protective mechanisms and damping of the device response, so these mechanisms have limitations. Dropping a device can expose it to accelerations of up to 400 g, which is difficult to accommodate for in a low-range device. The overrange limit is usually specified by the manufacturer.

As gravity is acceleration toward the center of the Earth, accelerometers that have a DC response are sensitive to gravity. An accelerometer at rest or in steady-state motion (i.e., not subject to other accelerations caused by motion) with its sensitive axis pointing toward the center of the Earth will have an output equal to 1 g. This property is commonly used to calibrate the gain and zero offset of an accelerometer by positioning the sensitive axis at a known
angle relative to vertical and measuring the output.

High-frequency accelerometers, such as piezoelectric accelerometers, have a small physical size to ensure a high natural frequency (above 10 kHz). They are used in applications such as vibration and impact monitoring.

Devices that provide the best DC response include piezoresistive, capacitive, force balance, and thermal accelerometers. These devices would be used in navigation and robotic applications as tilt sensors, constant acceleration measurements, or sensors taking measurements over prolonged periods.

Table 1 summarizes some typical performance characteristics of devices used for biomedical
applications.

4. PHYSICAL FEATURES

Semiconductor accelerometers are often MEMS, which are a combination of mechanical and electrical components made from silicon using micromachining processes. Piezoelectric devices are usually machined and packaged with necessary electronic components for filtering and
amplifying their output, and are therefore referred to as Integrated Electronics Piezo Electric (IEPE) devices.

Semiconductor accelerometers measure acceleration in a variety of ways. Piezoresistive devices have resistive elements embedded in the spring components, which sense deflection as a change in resistance. Piezoelectric devices have a layer of material on the springs that responds to deflection with a change in electrical output. Others work like plate capacitors, with the silicon being machined into tiny comb-like structures that move with the attached mass when they are accelerated. The change in the distance between the combs causes a change in the electrical output. Capacitive devices have advantages of low power consumption, a wide range of operation, and low thermal sensitivity.

Some designs combine these technologies to form a force-balanced capacitive accelerometer, typically used in automotive technology. These devices measure the force required to maintain a proof mass in a central, preset position. One drawback of this design is that because they are closed-loop accelerometers, the feedback loop slows down the response time, resulting in a smaller bandwidth than other devices. However, they have other features that are desirable for high-precision applications, such as accuracy and high signal-to-noise ratios.

Thermal accelerometers have recently been developed that sense acceleration by changes in heat transfer between micromachined elements within a small, insulated space on a silicon wafer. Some rely on thermal sensing for a seismic mass; as the mass is accelerated toward a heat source within the device, heat flows from the source to the mass and is sensed as acceleration. Other thermal accelerometers have no mass or spring elements, and therefore they are not subject to the typical trade-off between size/ weight and sensitivity. They are made using MEMS technology, and are more cost effective than other mass and spring MEMS systems because of their ease of manufacturing. They are highly shock-resistant (reportedly up to 50,000 g) and are less prone to noise and drift than other MEMS devices. The main disadvantages of thermal devices are their limited frequency response (usually less than 100 Hz) and sensitivity of some designs to the temperature of their environment.

All electronic devices require power and a means to measure their output. The power requirements for accelerometers vary depending on the type of device. In general, piezoelectric devices require a current in the milliamp range, and have a preamplifier and signal conditioners packaged within the device. Especially for small devices, this input can have a significant thermal effect on the device, and therefore they require a warm-up period
before use.

Accelerometers are usually packaged in a case that allows them to be firmly adhered to the object being measured in order to minimize the effects of damping or vibration. The sensitive axis is indicated on the outside of the package. Multiple axis accelerometers are available, either as multiple single-axis devices within one package, or as an inherently multiple-axis device.

 Usually, the axes are aligned orthogonally (at right angles to each other), and the multiple axes are indicated on the package. The outer case is usually metal, such as stainless steel, titanium, or a composite, which serves to protect and seal internal components. Accelerometers come in a variety of forms and sizes, such as through-hole and surface mount packages for use on a circuit board (Small Outline Integrated Circuits, or SOICs). Others are in a self-contained form that can be attached directly to a data acquisition system or in a package that can be attached to the object whose acceleration is being measured. The forms typically include a tapped hole or stud (threaded or unthreaded), so they can be bolted securely to the object being monitored. Adhesives such as hot glue or double-sided tape can also be used to hold the device in position.

Depending on the inherent stiffness of the device, the amount of torque applied when bolting it in place can change the output. Care must be taken to ensure consistent mounting torque when taking measurements over time or when comparing measurements between locations
or devices.

Actual accelerometer sizes can be as small as a few hundred microns for MEMS devices, but the final size of the product is larger, typically several millimeters, because it is packaged together with the necessary electronics to amplify and process the output. The mass of the device should be small relative to the mass of the object being monitored. Otherwise, the behavior of the object may be affected, a condition referred to as mass loading. For some applications where size constraint is critical, or for high-frequency measurements, a miniature device may be required, generally considered to weigh less than 100 grams. Although these devices use advanced manufacturing methods and can be highly sensitive and accurate, there are trade-offs between size and stability, ruggedness and cost.

5. APPLICATIONS

The measurement of the acceleration of limb segments has been used for human motion analysis, motion detection, vibration, and impact studies. To measure the linear acceleration as well as the angular acceleration and angular velocity of the center of mass of a body segment in two or three dimensions, groupings of six to twelve linear accelerometers can be placed on a body segment such as the upper body (6) or the lower limb. However, it has been found that because of the magnitude of experimental errors, accelerometers alone may not be a reliable method of calculating limb kinematics, such as position and orientation.

 As semiconductor and MEMS technology develop, it is likely that accelerometers will become smaller, more sensitive, and more accurate. In fact, the performance capabilities of these devices has greatly improved over the past decade, and it is possible that this will lead to more
widespread use for human motion analysis.

Vibration studies have been conducted to examine the shock-absorbing properties of joints and soft tissue structures such as the spine and lower leg. Accelerometers can quantify the accelerations being sensed by these parts of the body and the shock attenuation that takes place within the soft tissue structures. This information is useful for establishing the long-term effects of exposure to low-level vibrations such as lower back pain and other musculoskeletal disorders. Although industrial vibration sensors require a high bandwidth, those used for human body vibration monitoring are typically below 60 Hz. Studies of accelerations caused by impact during normal walking and running have found accelerations of up to 10 g during running, with a frequency range of up to 100 Hz, which has significance in the area of athletic shoe design, as well as the study of tissue damage caused by high impact.
Detection of motion and the initiation of movement have been investigated by researchers for position feedback in systems being investigated to restore gait for paraplegics and stroke victims. With functional neuromuscular stimulation (FNS), the lower limbs are stimulated to move, and accelerometers provide feedback on body segment and joint positions. Another application of accelerometers in motion detection is for monitoring balance during walking. Accelerometers and gyroscopes, which measure angular velocity, can be combined to form an inertial sensing system that works similarly to the human vestibular system, providing complete information on linear and angular accelerations. Several researchers and manufacturers are investigating ways to combine three-axis accelerometers and gyroscopes into a six-degree of freedom inertial sensing device.

One of the most common biomedical applications of accelerometers is in the area of physical activity monitoring. The use of accelerometer-based monitors is gaining widespread acceptance as a means to monitor physical activity of patients undergoing rehabilitation or treatment for mobility-related disorders, as well as activity of the general public. Accelerometer-based pedometers log the number of acceleration spikes identified as ‘‘steps,’’ And are readily available to consumers through several manufacturers.

Other accelerometer systems are used by physical activity researchers to discern not only the number of movements, but the type of activity, such as sitting, standing, lying down, and dynamic activity. These are sometimes referred to as activities of daily living (ADL) monitors. The accelerometer unit is strapped somewhere on the trunk and is wired to a separate data logger, which stores and displays the cumulative data. These typically use a time-frequency analysis to establish the duration of the different activities. The latest research efforts in physical activity monitoring are focused on discriminating between different dynamic activities, such as walking and stair climbing, which cannot be achieved with currently available devices.

Human motion, biofeedback, and wireless computer interfaces all make use of accelerometers as tilt sensors, which measure the direction of an object relative to the ground. Future applications include tilt sensors for easier manipulation of handheld devices such as cell phones and personal digital assistants (PDAs). Researchers are investigating data entry to a device by a combination of tilting it in different directions and allowing multiple devices to communicate by tapping them together like champagne glasses, which holds promise for use in for adaptive  devices for the disabled and feedback devices for rehabilitation.






Wednesday, October 9, 2013

100 Keyboard Shortcuts for Windows 8





The Human Heart [ANATOMY/PHYSIOLOGY/CONDUCTION SYSTEM]

THE HUMAN HEART

The heart is a muscular organ about the size of a closed fist that functions as the body’s circulatory pump. It takes in deoxygenated blood through the veins and delivers it to the lungs for oxygenation before pumping it into the various arteries (which provide oxygen and nutrients to body tissues by transporting the blood throughout the body). The heart is located in the thoracic cavity medial to the lungs and posterior to the sternum.

On its superior end, the base of the heart is attached to the aorta, pulmonary arteries and veins, and the vena cava. The inferior tip of the heart, known as the apex, rests just superior to the diaphragm. The base of the heart is located along the body’s midline with the apex pointing toward the left side. Because the heart points to the left, about 2/3 of the heart’s mass is found on the left side of the body and the other 1/3 is on the right.

Anatomy of the Heart

Pericardium

The heart sits within a fluid-filled cavity called the pericardial cavity. The walls and lining of the pericardial cavity are a special membrane known as the pericardium. Pericardium is a type of serous membrane that produces serous fluid to lubricate the heart and prevent friction between the ever beating heart and its surrounding organs. Besides lubrication, the pericardium serves to hold the heart in position and maintain a hollow space for the heart to expand into when it is full. The pericardium has 2 layers—a visceral layer that covers the outside of the heart and a parietal layer that forms a sac around the outside of the pericardial cavity.

Structure of the Heart Wall
The heart wall is made of 3 layers: epicardium, myocardium and endocardium.
  • Epicardium. The epicardium is the outermost layer of the heart wall and is just another name for the visceral layer of the pericardium. Thus, the epicardium is a thin layer of serous membrane that helps to lubricate and protect the outside of the heart. Below the epicardium is the second, thicker layer of the heart wall: the myocardium.
     
  • Myocardium. The myocardium is the muscular middle layer of the heart wall that contains the cardiac muscle tissue. Myocardium makes up the majority of the thickness and mass of the heart wall and is the part of the heart responsible for pumping blood. Below the myocardium is the thin endocardium layer.
     
  • Endocardium. Endocardium is the simple squamous endothelium layer that lines the inside of the heart. The endocardium is very smooth and is responsible for keeping blood from sticking to the inside of the heart and forming potentially deadly blood clots.
The thickness of the heart wall varies in different parts of the heart. The atria of the heart have a very thin myocardium because they do not need to pump blood very far—only to the nearby ventricles. The ventricles, on the other hand, have a very thick myocardium to pump blood to the lungs or throughout the entire body. The right side of the heart has less myocardium in its walls than the left side because the left side has to pump blood through the entire body while the right side only has to pump to the lungs.

Chambers of the Heart
The heart contains 4 chambers: the right atrium, left atrium, right ventricle, and left ventricle. The atria are smaller than the ventricles and have thinner, less muscular walls than the ventricles. The atria act as receiving chambers for blood, so they are connected to the veins that carry blood to the heart. The ventricles are the larger, stronger pumping chambers that send blood out of the heart. The ventricles are connected to the arteries that carry blood away from the heart.
The chambers on the right side of the heart are smaller and have less myocardium in their heart wall when compared to the left side of the heart. This difference in size between the sides of the heart is related to their functions and the size of the 2 circulatory loops. The right side of the heart maintains pulmonary circulation to the nearby lungs while the left side of the heart pumps blood all the way to the extremities of the body in the systemic circulatory loop.
Valves of the Heart
The heart functions by pumping blood both to the lungs and to the systems of the body. To prevent blood from flowing backwards or “regurgitating” back into the heart, a system of one-way valves are present in the heart. The heart valves can be broken down into two types: atrioventricular and semilunar valves.
  • Atrioventricular valves. The atrioventricular (AV) valves are located in the middle of the heart between the atria and ventricles and only allow blood to flow from the atria into the ventricles. The AV valve on the right side of the heart is called the tricuspid valve because it is made of three cusps (flaps) that separate to allow blood to pass through and connect to block regurgitation of blood. The AV valve on the left side of the heart is called the mitral valve or the bicuspid valve because it has two cusps. The AV valves are attached on the ventricular side to tough strings called chordae tendineae. The chordae tendineae pull on the AV valves to keep them from folding backwards and allowing blood to regurgitate past them. During the contraction of the ventricles, the AV valves look like domed parachutes with the chordae tendineae acting as the ropes holding the parachutes taut.
     
  • Semilunar valves. The semilunar valves, so named for the crescent moon shape of their cusps, are located between the ventricles and the arteries that carry blood away from the heart. The semilunar valve on the right side of the heart is the pulmonary valve, so named because it prevents the backflow of blood from the pulmonary trunk into the right ventricle. The semilunar valve on the left side of the heart is the aortic valve, named for the fact that it prevents the aorta from regurgitating blood back into the left ventricle. The semilunar valves are smaller than the AV valves and do not have chordae tendineae to hold them in place. Instead, the cusps of the semilunar valves are cup shaped to catch regurgitating blood and use the blood’s pressure to snap shut.
Conduction System of the Heart
The heart is able to both set its own rhythm and to conduct the signals necessary to maintain and coordinate this rhythm throughout its structures. About 1% of the cardiac muscle cells in the heart are responsible for forming the conduction system that sets the pace for the rest of the cardiac muscle cells.
The conduction system starts with the pacemaker of the heart—a small bundle of cells known as the sinoatrial (SA) node. The SA node is located in the wall of the right atrium inferior to the superior vena cava. The SA node is responsible for setting the pace of the heart as a whole and directly signals the atria to contract. The signal from the SA node is picked up by another mass of conductive tissue known as the atrioventricular (AV) node.
The AV node is located in the right atrium in the inferior portion of the interatrial septum. The AV node picks up the signal sent by the SA node and transmits it through the atrioventricular (AV) bundle. The AV bundle is a strand of conductive tissue that runs through the interatrial septum and into the interventricular septum. The AV bundle splits into left and right branches in the interventricular septum and continues running through the septum until they reach the apex of the heart. Branching off from the left and right bundle branches are many Purkinje fibers that carry the signal to the walls of the ventricles, stimulating the cardiac muscle cells to contract in a coordinated manner to efficiently pump blood out of the heart.

Physiology of the Heart

Coronary Systole and Diastole
At any given time the chambers of the heart may found in one of two states:
  • Systole. During systole, cardiac muscle tissue is contracting to push blood out of the chamber.
     
  • Diastole. During diastole, the cardiac muscle cells relax to allow the chamber to fill with blood. Blood pressure increases in the major arteries during ventricular systole and decreases during ventricular diastole. This leads to the 2 numbers associated with blood pressure—systolic blood pressure is the higher number and diastolic blood pressure is the lower number. For example, a blood pressure of 120/80 describes the systolic pressure (120) and the diastolic pressure (80).
The Cardiac Cycle
The cardiac cycle includes all of the events that take place during one heartbeat. There are 3 phases to the cardiac cycle: atrial systole, ventricular systole, and relaxation.
  • Atrial systole: During the atrial systole phase of the cardiac cycle, the atria contract and push blood into the ventricles. To facilitate this filling, the AV valves stay open and the semilunar valves stay closed to keep arterial blood from re-entering the heart. The atria are much smaller than the ventricles, so they only fill about 25% of the ventricles during this phase. The ventricles remain in diastole during this phase.
     
  • Ventricular systole: During ventricular systole, the ventricles contract to push blood into the aorta and pulmonary trunk. The pressure of the ventricles forces the semilunar valves to open and the AV valves to close. This arrangement of valves allows for blood flow from the ventricles into the arteries. The cardiac muscles of the atria repolarize and enter the state of diastole during this phase.
     
  • Relaxation phase: During the relaxation phase, all 4 chambers of the heart are in diastole as blood pours into the heart from the veins. The ventricles fill to about 75% capacity during this phase and will be completely filled only after the atria enter systole. The cardiac muscle cells of the ventricles repolarize during this phase to prepare for the next round of depolarization and contraction. During this phase, the AV valves open to allow blood to flow freely into the ventricles while the semilunar valves close to prevent the regurgitation of blood from the great arteries into the ventricles.
Blood Flow through the Heart

Pulmonary Circulation
Deoxygenated blood returning from the body first enters the heart from the superior and inferior vena cava. The blood enters the right atrium and is pumped through the tricuspid valve into the right ventricle. From the right ventricle, the blood is pumped through the pulmonary semilunar valve into the pulmonary trunk.
The pulmonary trunk carries blood to the lungs where it releases carbon dioxide and absorbs oxygen. The blood in the lungs returns to the heart through the pulmonary veins. From the pulmonary veins, blood enters the heart again in the left atrium.

Systemic Circulation
The left atrium contracts to pump blood through the bicuspid (mitral) valve into the left ventricle. The left ventricle pumps blood through the aortic semilunar valve into the aorta. From the aorta, blood enters into systemic circulation throughout the body tissues until it returns to the heart via the vena cava and the cycle repeats.

The Electrocardiogram
The electrocardiogram (also known as an EKG or ECG) is a non-invasive device that measures and monitors the electrical activity of the heart through the skin. The EKG produces a distinctive waveform in response to the electrical changes taking place within the heart.
The first part of the wave, called the P wave, is a small increase in voltage of about 0.1 mV that corresponds to the depolarization of the atria during atrial systole. The next part of the EKG wave is the QRS complex which features a small drop in voltage (Q) a large voltage peak (R) and another small drop in voltage (S). The QRS complex corresponds to the depolarization of the ventricles during ventricular systole. The atria also repolarize during the QRS complex, but have almost no effect on the EKG because they are so much smaller than the ventricles.
The final part of the EKG wave is the T wave, a small peak that follows the QRS complex. The T wave represents the ventricular repolarization during the relaxation phase of the cardiac cycle. Variations in the waveform and distance between the waves of the EKG can be used clinically to diagnose the effects of heart attacks, congenital heart problems, and electrolyte imbalances.

Heart Sounds
The sounds of a normal heartbeat are known as “lubb” and “dupp” and are caused by blood pushing on the valves of the heart. The “lubb” sound comes first in the heartbeat and is the longer of the two heart sounds. The “lubb” sound is produced by the closing of the AV valves at the beginning of ventricular systole. The shorter, sharper “dupp” sound is similarly caused by the closing of the semilunar valves at the end of ventricular systole. During a normal heartbeat, these sounds repeat in a regular pattern of lubb-dupp-pause. Any additional sounds such as liquid rushing or gurgling indicate a structure problem in the heart. The most likely causes of these extraneous sounds are defects in the atrial or ventricular septum or leakage in the valves.

Cardiac Output
Cardiac output (CO) is the volume of blood being pumped by the heart in one minute. The equation used to find cardiac output is: CO = Stroke Volume x Heart Rate
Stroke volume is the amount of blood pumped into the aorta during each ventricular systole, usually measured in milliliters. Heart rate is the number of heartbeats per minute. The average heart can push around 5 to 5.5 liters per minute at rest.










                                       FIGURES ABOVE SHOW HEART ANATOMY







FIGURE : BLOOD CIRCULATION AND PHYSIOLOGY



 
 FIGURE : CONDUCTION SYSTEM OF HEART