Saturday, April 13, 2013

AUDIOSPOTLIGHT REVISITED

AUDIOSPOTLIGHT REVISITED

Audio spot lighting is a very recent technology that creates focused beams of sound similar to light beams coming out of a flashlight. By „shining‟ sound to one location, specific listeners can be targeted with sound without others nearby hearing it. It uses a combination of non-linear acoustics and some fancy mathematics. But it is real and is fine to knock the socks of any conventional loud speaker. This acoustic device comprises a speaker that fires inaudible ultrasound pulses with very small wavelength which act in a manner very similar to that of a narrow column. The ultra sound beam acts as an airborne speaker and as the beam moves through the air gradual distortion takes place in a predictable way due to the property of non-linearity of air. This gives rise to audible components that can be accurately predicted and precisely controlled. Joseph Pompei‟s Holosonic Research Labs invented the Audio Spotlight that is made of a sound processor, an amplifier and the transducer. The American Technology Corporation developed the Hyper Sonic Sound-based Directed Audio Sound System. Both use ultrasound based solutions to beam sound into a focused beam. Audio spotlight can be either directed at a particular listener or to a point where it is reflected.

The targeted or directed audio technology is going to a huge commercial market in entertainment and consumer electronics and technology developers are scrambling to tap in to the market. Being the most recent and dramatic change in the way we perceive sound since the invention of coil loud speaker, audio spot light technology can do many miracles in various fields like Private messaging system, Home theatre audio system, Navy and military applications, museum displays, ventriloquist systems etc. Thus audio spotlighting helps us to control where sound comes from and where it goes!

WHAT IS AUDIO SPOTLIGHTING?
.
The Audio Spotlight & Hyper Sonic Sound Technology (developed by American Technology Corporation), uses ultrasonic energy to create extremely narrow beams of sound that behave like beams of light. Audio spotlighting exploits the property of non-linearity of air. When inaudible ultrasound pulses are fired into the air, it spontaneously converts the inaudible ultrasound into audible sound tones, hence proved that as with water, sound propagation in air is just as non-linear, and can be calculated mathematically. A device known as a parametric array employs the non-linearity of the air to create audible by-products from inaudible ultrasound, resulting in an extremely directive, beam-like wide-band acoustical source. This source can be projected about an area much like a spotlight, and creates an actual specialized sound distant from the transducer. The ultrasound column acts as an airborne speaker, and as the beam moves through the air, gradual distortion takes place in a predictable way. This gives rise to audible components that can be accurately predicted and precisely controlled.

THEORY

What ordinary audible sound & Conventional Loud Speakers lack? What we need? About a half-dozen commonly used speaker types are in general use today. They range from piezoelectric tweeters that recreate the high end of the audio spectrum, to various kinds of midrange speakers and woofers that produce the lower frequencies. Even the most sophisticated hi-fi speakers have a difficult time in reproducing clean bass, and generally rely on a large woofer/enclosure combination to assist in the task. Whether they be dynamic, electrostatic, or some other transducer-based design, all loudspeakers today have one thing in common: they are direct radiating-- that is, they are fundamentally a piston-like device designed to directly pump air molecules into motion to create the audible sound waves we hear. The audible portions of sound tend to spread out in all directions from the point of origin. They do not travel as narrow beams—which is why you don‟t need to be right in front of a radio to hear music. In fact, the beam angle of audible sound is very wide, just about 360 degrees. This effectively means the sound that you hear will be propagated through air equally in all directions.

In order to focus sound into a narrow beam, you need to maintain a low beam angle that is dictated by wavelength. The smaller the wavelength, the less the beam angle, and hence, the more focused the sound. Unfortunately, most of the human-audible sound is a mixture of signals with varying wavelengths—between 2cms to 17 meters (the human hearing ranges from a frequency of 20 Hz to 20,000 Hz). Hence, except for very low wavelengths, just about the entire audible spectrum tends to spread out at 360 degrees. To create a narrow sound beam, the aperture size of the source also matters—a large loudspeaker will focus sound over a smaller area. If the source loudspeaker can be made several times bigger than the wavelength of the sound
transmitted, then a finely focused beam can be created. The problem here is that this is not a very practical solution. To ensure that the shortest audible wavelengths are focused into a beam, a loudspeaker about 10 meters across is required, and to guarantee that all the audible wavelengths are focused, even bigger loudspeakers are needed.

Here comes the acoustical device “AUDIO SPOTLIGHT” invented by Holosonics Labs founder Dr. F. Joseph Pompei (while a graduate student at MIT), who is the master brain behind the development of this technology.
 

FIGURE : AUDIO SPOTLIGHT CREATES FOCUSED BEAM OF SOUND UNLIKE CONVENTIONAL LOUD SPEAKERS

Audio spotlight looks like a disc-shaped loudspeaker, trailing a wire, with a small laser guide beam mounted in the middle. When one points the flat side of the disc in your direction, you hear whatever sound he's chosen to play for you — perhaps jazz from a CD. But when he turns the disc away, the sound fades almost to nothing. It's markedly different from a conventional speaker, whose orientation makes much less difference.

FIGURE : F.JOSEPH POMPEI AT THE MEDIA LAB OF THE MASSACHUSETTS INSTITUTE OF TECHNOLOGY DEMONSTRATES HOW INVISIBLE ULTRASONIC WAVES, AS ILLUSTRATED HERE, COULD HELP "STEER" SOUND. (ABCNEWS.COM)

TECHNOLOGY OVERVIEW

The Audio Spotlight & Hyper Sonic Sound Technology (developed by American Technology Corporation), uses ultrasonic energy to create extremely narrow beams of sound that behave like beams of light. Ultrasonic sound is that sound that has very small wavelength—in the millimeter range and you can‟t hear ultrasound since it lies beyond the threshold of human hearing.

COMPONENTS AND SPECIFICATIONS

Audio Spotlight consists of three major components: a thin, circular transducer array, a signal processor and an amplifier. The lightweight, nonmagnetic transducer is about .5 inches (1.27 centimeters) thick, and it typically has an active area 1 foot (30.48 cm) in diameter. It can project a three-degree wide beam of sound that is audible even at distances over 100 meters (328 feet). The signal processor and amplifier are integrated into a system about the size of a traditional audio amplifier, and they use about the same amount of power.

SOUND BEAM PROCESSOR/AMPLIFIER
  1. Worldwide power input standard
  2. Standard chassis 6.76”/171mm (w) x 2.26”/57mm (h)x 11”/280mm (d), optional rack mount kit
  3. Audio input: balanced XLR, 1/4” and RCA (with BTW adapter) Custom configurations available eg. Multichannel
AUDIO SPOTLIGHT TRANSDUCER
  1.  17.5”/445mm diameter, 1/2”/12.7mm thick, 4lbs/1.82kg
  2.  Wall, overhead or flush mounting
  3.  Black cloth cover standard, other colors available
  4.  Audio output: 100dB max
  5.  ~1% THD typical @ 1kHz
  6.  Usable range: 20m
  7.  Audibility to 200m
  8.  Optional integrated laser aimer 13”/ 330.2mm and 24”/ 609.6mm diameter also available
  9.  Fully CE compliant
  10.  Fully real time sound reproduction - no processing lag
  11. Compatible with standard loudspeaker mounting accessories Due to continued development, specifications are subject to change. 
 NON-LINEARITY OF AIR

Audio spotlighting exploits the property of non-linearity of air. When inaudible ultrasound pulses are fired into the air, it spontaneously converts the inaudible ultrasound into audible sound tones, hence proved that as with water, sound propagation in air is just as non-linear, and can be calculated mathematically. A device known as a parametric array employs the non-linearity of the air to create audible by-products from inaudible ultrasound, resulting in an extremely directive, beamlike wide-band acoustical source. This source can be projected about an area much like a spotlight, and creates an actual specialized sound distant from the transducer. The ultrasound column acts as an airborne speaker, and as the beam moves through the air, gradual distortion takes place in a predictable way. This gives rise to audible components that can be accurately predicted and precisely controlled. However, the problem with firing off ultrasound pulses, and having them interfere to produce audible tones is that the audible components created are nowhere similar to the complex signals in speech and music. Human speech, as well as music, contains multiple varying frequency signals, which interfere to produce sound and distortion. To generate such sound out of pure ultrasound tones is not easy. This is when teams of researchers from Ricoh and other Japanese companies got together to come up with the idea of using pure ultrasound signals as a carrier wave, and superimposing audible speech and music signals on it to create a hybrid wave. If the range of human hearing is expressed as a percentage of shifts from the lowest audible frequency to the highest, it spans a range of 100,000%. No single loudspeaker element can operate efficiently or uniformly over this range of frequencies. In order to deal with this speaker manufacturers carve the audio spectrum into smaller sections. This requires multiple transducers and crossovers to create a 'higher fidelity' system with current technology.

 FIGURE: PARAMETRIC LOUDSPEAKER- AMAZING AUDIO SPOTLIGHT

(Airborne ultrasounds of 28kHz are envelope-modulated with audio signals. Inherent non-linearity of the air works as a de-modulator. Thus de-modulated sounds impinge on our eardrums. We can hear those sounds! )
Using a technique of multiplying audible frequencies upwards and superimposing them on a "carrier" of say, 200,000 cycles the required frequency shift for a transducer would be only 10%. Building a transducer that only needs to produce waves uniformly over only a 10% frequency range.

For example, if a loudspeaker only needed to operate from 1000 to 1100 Hz (10%), an almost perfect transducer could be designed.
 

 FIGURE: DIFFERENCE IN MODULATING AUDIBLE FREQUENCIES
WITH ULTRASONIC CARRIER

This is similar to the idea of amplitude modulation (AM), a technique used to broadcast commercial radio stations signals over a wide area. The speech and music signals are mixed with the pure ultrasound carrier wave, and the resultant hybrid wave is then broadcast. As this wave moves through the air, it creates complex distortions that give rise to two new frequency sets, one slightly higher and one slightly lower than the hybrid wave. Berktay‟s equation holds strong here, and these two sidebands interfere with the hybrid wave and produce two signal components, as the equation says. One is identical to the original sound wave, and the other is a badly distorted component. This is where the problem lies—the volume of the original sound wave is proportional to that of the ultrasounds, while the volume of the signal‟s distorted component is exponential. So, a slight increase in the volume drowns out the original sound wave as the distorted signal becomes predominant. It was at this point that all research on ultrasound as a carrier wave for an audio spotlight got bogged down in the 1980s.

Focusing on the signal‟s distorted component, since the signal component‟s behavior is mathematically predictable, the technique to create the audio beam is simple; modulate the amplitude to get the hybrid wave, then calculate what the Becktay‟s Equation does to this signal, and do the exact opposite. In other words, distort it, before Mother Nature does it. Finally, pass this wave through air and what you get is the original sound wave component whose original volume, this time, is, exponentially related to the volume of ultrasound beam and a distorted component whose volume now varies directly as the ultrasound wave. By creating a complex ultrasound waveform (using a parametric array of ultrasound sources), many different sources of sound can be created. If their phases are carefully controlled, then these interfere destructively laterally and constructively in the forward direction, resulting in a collimated sound beam or audio spotlight. Today, the transducers required to produce these beams are just half an inch thick and lightweight, and the system required to drive it has similar power requirements to conventional amplifier technology


FIGURE: COMPUTER SIMULATION OF SOUND PROPAGATION: COMPLEX SET OF
HIGH-INTENSITY ULTRASOUND SIGNALS INTER MODULATE AIR. AMONG THE
PRODUCTS IS A COLLIMATED AUDIO "SPOTLIGHT". 


DIRECT AUDIO AND PROJECTED AUDIO

There are two ways to use Audio Spotlight. First, it can direct sound at a specific target,creating a contained area of listening space which is called “Direct Audio”. Second, it can bounce off of a second object, creating an audio image. This audio image gives the illusion of a loudspeaker, which the listener perceives as the source of sound, which is called “projected Audio”. This is similar to the way light bounces off of objects. In either case, the sound‟s source is not the physical device you see, but the invisible ultrasound beam that generates it.

 

FIGURE: DIRECT AUDIO AND PROJECTED AUDIO

Hyper Sonic Sound technology provides linear frequency response with virtually none of the forms of distortion associated with conventional speakers. Physical size no longer defines fidelity. The faithful reproduction of sound is freed from bulky enclosures. There are no, woofers, tweeters, crossovers, or bulky enclosures. Thus it helps to visualize the traditional loudspeaker as a light bulb, and HSS technology as a spotlight, that is you can direct the ultrasonic emitter toward a hard surface, a wall for instance, and the  listener perceives the sound as coming from the spot on the wall. The listener does not perceive the sound as emanating from the face of the transducer, only from the reflection off the wall.

Contouring the face of the HSS ultrasonic emitter can tightly control Dispersion of the audio wave front. For example, a very narrow wave front might be developed for use on the two sides of a computer screen while a home theater system might require a broader wave front to envelop multiple listeners.

 

FIGURE:  CONVENTIONAL LOUDSPEAKER & ULTRASONIC EMITTER

SPECIAL FEATURES OF AUDIO SPOTLIGHT: A COMPARISON WITH CONVENTIONAL LOUD SPEAKER

  1. Creates highly FOCUSED BEAM of sound
  2. Sharper directivity than conventional loud speakers using Self demodulation of finite amplitude ultrasound with very small wavelength as the carrier
  3. Uses inherent non-linearity of air for demodulation
  4. Components- A thin circular transducer array, a signal processor & an amplifier.
  5. Two ways to use- Direct & projected audio
  6. Wide range of applications
  7. Highly cost effective
APPLICATIONS OF AUDIO SPOTLIGHTING -TOWARDS THE FUTURE

"So you can control where your sound comes from and where it goes," says Joe Pompei, the inventor of Audio Spotlight. , Pompei was awarded a “Top Young Innovator” award from Technology Review Magazine for his achievements.

The targeted or directed audio technology is going to tap a huge commercial market in entertainment and in consumer electronics, and the technology developers are scrambling to tap into that market. Analysts claim that this is possibly the most dramatic change in the way we perceive sound since the invention of the coil loudspeaker. The technology that the Holosonics Research Labs and the American Technology Corporation are lining up may seem to be a novelty of sorts, but a wide range of applications are being targeted at it.

Continuing to improve on the commercial success of the Audio Spotlight sound system, Holosonics has announced that its next-generation laser-like sound system, with improved performance and lower cost, is now actively in production. These new systems are being exhibited at the 2004 Consumer Electronics Show in Las Vegas alongside MIT Media Lab technology.

  1. The performance and reliability of the Audio Spotlight have made it the choice of the Smithsonian Institution, Motorola, Kraft, and Cisco Systems etc.
  2. Holosonics put in four individual Audio Spotlights into the Daimler Chrysler MAXXcab prototype truck to let all the passengers enjoy their own choice of music. Boston Museum of Science - as well as the United States military.
  3. There is an even bigger market for personalized sound systems in entertainment and consumer electronics.
  4. Holosonic Labs is working on another interesting application at the Boston Museum of Science that allows the intended listeners to understand and hear explanations, without raising the ambient sound levels. The idea is that museum exhibits can be discretely wired up with tiny speaker domes that can unobtrusively, provide explanations.
  5. There are also other interesting applications that they are looking at, such as private messaging using this system without headphones special effects at presentations as well as special sound theme parks that could put up animated sound displays similar to today‟s light shows. Holosonic has installed their Audio Spotlight system at Tokyo‟s Sega Joyopolis theme park.
  6. The US Navy has installed sound beaming technology on the deck of an Aegis-class Navy destroyer, and is looking at this as a substitute to the radio operator‟s headphones.

CONCLUSION

“Being the most radical technological development in acoustics since the coil loudspeaker was invented in 1925... The audio spotlight will force people to rethink their relationship with sound…”

-New York Times

So we can conclude- Audio Spotlighting really “put sound where you want it” and will be “A REAL BOON TO THE FUTURE.”

Tuesday, February 19, 2013

Download Chemical and Biosensors by brain r eggins

Please download the file from under given links chemical and bio sensors by brain r eggins.pdf

Upload Files

VIRTUAL RETINAL DISPLAY

VIRTUAL RETINAL DISPLAY
by
Neeraj Shukla(B.C.A. III Year, S.J.I.M.S.)
Souvik Ghosh(B.C.A. III Year, S.J.I.M.S.)

ABSTRACT

The Virtual Retinal Display™ (VRD™) technology is a new display technology being developed at Microvision Inc. The displayed image is scanned onto the viewer’s retina using low-power red, green, and blue light sources. Microvision’s proprietary miniaturized scanner designs make VRD system very well suited for head-mounted displays. In this paper we discuss some of the advantages of the VRD technology, various ocular designs for HMD and other applications, and details of constructing a system MTF budget for laser scanning systems that includes electronics, modulators, scanners, and optics.
Keywords: laser scanning, display resolution, Virtual Retinal Display, VRD, head mounted displays, modulation transfer function
1. Introduction
Virtual Retinal Display™ (VRD™) technology is a novel scanning-based display technology where the displayed image is scanned in a raster format onto the viewer’s retina in a raster pattern using low-power red, green, and blue light sources, such as lasers, laser diodes, or LEDs. The VRD systems use two uniaxial scanners or one biaxial scanner to create a raster pattern. The horizontal scanner is a flexure-based mechanical resonant scanner that operates at several KHz and the vertical scanner is also a mechanical scanner operated at a non-resonant mode at the frame rate of the display, which is typically 60Hz
.
The resolution and the modulation transfer function (MTF) are key performance indicators in display systems. Resolution of mechanical scanners is proportional to scan mirror size and scan angle, and inversely proportional to wavelength. High-resolution systems demand horizontal scanners that provide a large mirror-size scan-angle product and high frequency. System resolution issues and scanner design issues are discussed in more detail elsewhere.
This paper is divided into three parts. In the first part, we briefly discuss the VRD system operation and its advantages compared to other display technologies. The second part is dedicated to VRD ocular designs for HMD applications and the MTF performance of different ocular designs. In the last part, we give formulas that are used compute the MTF contributions of electronics, modulators, pixel duty-cycle, and scanner optics, then we illustrate how to construct a system MTF budget for the horizontal and the vertical axes in laser scanning display systems.
VRD Emulator Test System
This project represents a continuing are of interest at the HIT Lab, though it is not currently funded. Virtual Retinal Display (VRD) scans intensity modulated laser light pixels directly onto retina. Each pixel is modulated in short pulses of 30ns to 40ns. The input light is a combined beam from three different wavelengths of laser light, which produces a color gamut exceeding that of a conventional CRT. The area covered by the laser spot on the back of the retina for the duration of a single pixel is called a 'retinel'.
Unlike CRT monitors, the VRD has no phosphor persistence but depends on the light-gathering properties of the photoreceptors and the temporal integration properties of the visual system. Therefore, the interactions between the VRD delivered light and the psychophysical image quality created by the brain are of extreme importance for future enhancements.
The enhanced image quality of the VRD is believed to be the result of several system properties:
1. Small exit pupil which gives large depth of focus.
2. Beam size which minimizes optical aberrations at cornea .
3. Laser light penetrates mild to moderate media opacities with minimal scattering .
4. High luminance and high color contrast .
5. Collimation and coherence of the light.
6. Decreased flicker sensitivity.
7. No perceptual laser speckle.
Unfortunately, the current VRD design does not provide a way to test many of the these system properties. Therefore an Emulator of the VRD has been developed.
The emulator system requires a scanned light sources of the emulator to be modulated by passing the light through a 35mm slide. This provides us with the capability to:
· Vary spot size at the retina.
· Vary the spacing between between horizontal lines
· Vary the spacing between pixels
· Vary scan rates of the system
· Investigate coherent versus incoherent light
· Control light intensity
· Use a common source of modulation
· Match laser lines of VRD (645, 514, 472 nm)and other color combinations
· Characterize optical parameters
· Automate data collection
Our predicted results include:
· Contrast sensitivity at lower spatial frequencies will be higher.
· Possible shift at higher spatial frequencies but not as likely.
· Subject's critical flicker thresholds should be consistently higher with the VRD relative to the CRT.
· Retinels size should be able to approach foveal cone spacing.
· As retinels approach cone spacing line separation will become less tolerant.
· Light coherence will have minimal effect on the enhanced performance. The point and angle of entrance beams at the corneal surface will be identified as major contributors to the enhanced performance.
THE VRD GROUP AND RESEARCH
The Virtual Retinal Display (VRD) team has been focused on developing improvements to the current prototype systems and on creating the parts needed for future prototypes. The VRD, based on the concept of scanning an image directly on the retina of the vi ewer's eye, was invented at the HIT Lab in 1991. The development program began in November 1993 with the goal of producing a full color, wide field-of-view, high resolution, high brightness, and low cost virtual display.
Two prototype systems are currently being demonstrated. The first is a bench-mounted unit that displays a full color, VGA (640 by 480) resolution image updated at 60 Hertz. It operates in either an inclusive or see-through mode. The second is a portable u nit, displaying a monochrome, VGA resolution image. The portable system is housed in a briefcase allowing for system demonstrations at remote locations (see photo above).
Techniques that expand the system's exit pupil, making it easier to align one's eye to the display, have been developed and demonstrated for a monochrome display. Work is continuing to optimize the design and to develop components that will expand the pupil of the color system.
The largest component in the portable system is the commercially purchased vertical (60 Hertz) scanner. A new vertical scanner is being designed that should significantly decrease devices size and cost. Once this design is complete a head-mounted demonstr ation prototype will be assembled.
Commercial applications of the VRD are being developed at Microvision Inc.
HOW THE VRD WORKS
Using the VRD technology it is possible to build a display with the following characteristics:
· Very small and lightweight, glasses mountable.
· Large field of view, greater than 120 degrees.
· High resolution, approaching that of human vision.
· Full color with better color resolution than standard displays.
· Brightness sufficient for outdoor use.
· Very low power consumption.
· True stereo display with depth modulation.
· Capable of fully inclusive or see through display modes
In a conventional display a real image is produced. The real image is either viewed directly or projected through an optical system and the resulting virtual image is viewed. With the VRD no real image is ever produced. Instead, an image is formed directly on the retina of the user's eye. A block diagram of the VRD is shown below. To create an image with the VRD a photon source (or three sources in the case of a color display) is used to generate a coherent beam of light. The use of a coherent source (such as a laser diode) allows the system to draw a diffraction limited spot on the retina. The light beam is intensity modulated to match the intensity of the image being rendered. The modulation can be accomplished after the beam is generated or, if the source has enough modulation bandwidth, as is the case with a laser diode, the source can be modulated directly.
The resulting modulated beam is then scanned to place each image point, or pixel, at the proper position on the retina. A variety of scan patterns are possible. The scanner could be used in a calligraphic mode, in which the lines that form the image are drawn directly, or in a raster mode, much like standard computer monitors or television. Our development focuses on the raster method of scanning an image and allows the VRD to be driven by standard video sources. To draw the raster, a horizontal scanner moves the beam to draw a row of pixels. The vertical scanner then moves the beam to the next line where another row of pixels is drawn.
In the original prototype the faster horizontal scanning is accomplished with an acoustic-optical modulator and the vertical scanning with a galvanometer to produce a 1280 pixel by 1024 line raster that is updated at 72 Hertz. The use of the acousto-optical modulator does, however, come with a number of drawbacks. First, it requires optics to shape the input beam for deflection and then additional optics to reform the output beam to the desired shape. Second, it requires complex drive electronics that operate at a very high frequency. Next, it has a very limited scan angle (4 degrees in our current prototype) such that additional optics are needed to increase the angle to the desired field-of-view. Due to the optical invariant, this optical increase in angle comes with the penalty of decreased beam diameter, which leads to a small exit pupil. The small exit pupil necessitates precise alignment with the eye for an image to be visible. Finally, the acousto-optical modulator is expensive and will not, in the foreseeable future, allow us to reach our cost goals for a complete VRD system
To overcome the limitations of the acousto-optical modulator HITL engineers have developed a proprietary mechanical resonant scanner. This scanner provides both horizontal and vertical scanning, with large scan angles, in a miniaturized package. The estimated recurring cost of this scanner will allow the VRD system to be priced competitively with other displays. A prototype VRD using the new mechanical resonant scanner has been developed and is currently being refined.
After scanning, the optical beam must be properly projected into the eye. The goal is for the exit pupil of the VRD to be coplanar with the entrance pupil of the eye. The lens of the eye will then focus this collimated light beam on the retina to form a spot. The position on the retina where the eye focuses a spot is determined by the angle at which light enters the eye. This angle is determined by the scanners and is constantly varying in a raster pattern. The intensity of the focused spot is determined by the intensity modulation of the light beam. The intensity modulated moving spot focused on the retina forms an image. The final portion of the system is the drive electronics, which must synchronize the scanners with the intensity modulators to form a stable image.
For 3-D viewing an image will be projected into both of the user's eyes. Each image will be created from a slightly different view point to create a stereo pair. With the VRD, it is also possible to vary the focus of each pixel in the image such that a true 3-D image is created. Thus, the VRD has the ability to generate an inclusive, high-resolution 3-D visual environment in a device the size of conventional eyeglasses.

Monday, January 31, 2011

Basic Electrode Theory and Nernst equation

Ion-Selective Electrodes are part of a group of relatively simple and inexpensive analytical tools which are commonly referred to as Sensors. The pH electrode is the most well known and simplest member of this group and can be used to illustrate the basic principles of ISEs. 

a) The pH Electrode
This is a device for measuring the concentration of hydrogen ions and hence the degree of acidity of a solution - since pH is defined as the negative logarithm of the hydrogen ion concentration; i.e. pH=7 means a concentration of 1x10-7 moles per litre. (To be more precise, the term ‘concentration’ should really be replaced by ‘activity’ or ‘effective concentration’. This is an important factor in ISE measurements. The difference between activity and concentration is explained in more detail later (Chapter 6), but it may be noted here that in dilute solutions they are essentially the same. Nevertheless, in order to avoid confusion, the more familiar term (concentration) will be used in this section.) 

The most essential component of a pH electrode is a special, sensitive glass membrane which permits the passage of hydrogen ions, but no other ionic species. When the electrode is immersed in a test solution containing hydrogen ions the external ions diffuse through the membrane until an equilibrium is reached between the external and internal concentrations. Thus there is a build up of charge on the inside of the membrane which is proportional to the number of hydrogen ions in the external solution.

Because of the need for equilibrium conditions there is very little current flow and so this potential difference can only be measured relative to a separate and stable reference system which is also in contact with the test solution, but is unaffected by it (see later for a discussion of reference electrodes). A sensitive, high impedance millivolt meter or digital measuring system must be used to measure this potential difference accurately.

The potential difference developed across the membrane is in fact directly proportional to the Logarithm of the ionic concentration in the external solution. Thus, in order to determine the pH of an unknown solution, it is only necessary to measure the potential difference in two standard solutions of known pH, construct a straight line calibration graph by plotting millivolts versus pH (= - Log [H+]) then read off the unknown pH from the measured voltage.

In order to measure the electrode potential developed at the ion-selective membrane the ISE/pH electrode must be immersed in the test solution together with a separate reference system and the two must be connected via a millivolt measuring system. At equilibrium, the electrons added or removed from the solution by the ISE membrane (depending on whether it is cation or anion sensitive) are balanced by an equal and opposite charge at the reference interface. This causes a positive or negative deviation from the original stable reference voltage which is registered on the external measuring system.

The relationship between the ionic concentration (activity) and the electrode potential is given by the Nernst equation:

E = E0 + (2.303RT/ nF) x Log(A)

Where 

E = the total potential (in mV) developed between the sensing and reference electrodes.
E0 = is a constant which is characteristic of the particular ISE/reference pair.
(It is the sum of all the liquid junction potentials in the electrochemical cell, see later)
2.303 = the conversion factor from natural to base10 logarithm.
R = the Gas Constant (8.314 joules/degree/mole).
T = the Absolute Temperature.
n = the charge on the ion (with sign).
F = the Faraday Constant (96,500 coulombs).
Log(A) = the logarithm of the activity of the measured ion.

Note that 2.303RT/nF is the Slope of the line (from the straight line plot of E versus log(A) which is the basis of ISE calibration graphs) and this is an important diagnostic characteristic of the electrode - generally the slope gets lower as the electrode gets old or contaminated, and the lower the slope the higher the errors on the sample measurements.

For practical use in measuring pH, it is not normally necessary for the operator to construct a calibration graph and interpolate the results for unknown samples. Most pH electrodes are connected directly to a special pH meter which performs the calibration automatically. This determines the slope mathematically and calculates the unknown pH value for immediate display on the meter.

These basic principles are exactly the same for all ISEs. Thus it would appear that all can be used as easily and rapidly as the pH electrode: i.e. simply by calibrating the equipment by measuring two known solutions, then immersing the electrodes in any test solution and reading the answer directly from a meter. Whilst it is certainly true that some other ions can be measured in this simple fashion, it is not the case for most. Unfortunately, some ISE advertising material tends to gloss over this fact and gives the reader a rather rosy view of the capabilities of this technique. There are several factors which can cause difficulties when ISE technology is applied to the measurement of other ions. These are listed below and discussed in more detail in later sections. Nevertheless, it must be stressed here that as long as these difficulties are recognised and steps are taken to overcome them, then ISEs can still be a very useful and cost-effective analytical tool.

b) Differences Between pH and Other Ion-Selective Electrodes

i) In contrast to the pH membrane, other ion-selective membranes are not entirely ion-specific and can permit the passage of some of the other ions which may be present in the test solution, thus causing the problem of ionic interference.

ii) Most ISEs have a much lower linear range and higher detection limit than the pH electrode. Many show a curved calibration line in the region 10-5 to 10-7 moles/l and very few can be used to determine concentrations below 1x10-7 moles/l. Thus, for low concentration samples, it may be necessary to construct a calibration graph with several points in order to define the slope more precisely in the non-linear range.

iii) The calculation of ionic concentration is far more dependent on a precise measurement of the potential difference than is the pH, because the pH depends on the order of magnitude of the concentration rather than the precise value. For example it would take an error of more than 5 millivolts to cause a change of 0.1 pH units, but only a 1 millivolt error will cause at least a 4% error in the calculated concentration of a mono-valent ion and more than 8% for a di-valent ion. This is because the theoretical value for the slope at 25°C is 59.2 for mono-valent ions and 29.6 for di-valent ions. In practical application, however these slopes can vary considerably because of variations in temperature, deviations from "ideal" behaviour, and minor impurities or contamination of the ion-selective membrane, or if samples are measured near the detection limit of the electrode, in the non-linear range. The critical factor is not so much the actual value of the slope but that this should be as high as possible and remain constant over the range of concentrations and the time period required for the analyses. Thus, when measuring other ion concentrations, it is essential to take extra precautions to minimise any errors in the measurement of the electrode potential.

iv) For ion concentration measurements, steps must be taken to minimise the effect of the Ionic Strength of the sample. This is because pH is defined as the log of the Activity of the ion (which is measured directly by any ISE) but most measurements of other ions require the actual concentration, which can differ significantly from activity in samples with complex matrices and high Ionic Strength.

v) It is more usual to plot a calibration graph using the ionic concentration with a logarithmic scale on the X-axis rather than the pX factor (analogous to pH) on a linear axis.

vi) Some ISEs will only work effectively over a narrow pH range.

REFERENCE ELECTRODES

In order to measure the change in potential difference across the ion-selective membrane as the ionic concentration changes, it is necessary to include in the circuit a stable reference voltage which acts as a half-cell from which to measure the relative deviations.

a) The Silver / Silver Chloride Single Junction Reference Electrode.
The most common and simplest reference system is the silver / silver chloride single junction reference electrode. This generally consists of a cylindrical glass tube containing a 4 Molar solution of KCl saturated with AgCl. The lower end is sealed with a porous ceramic frit which allows the slow passage of the internal filling solution and forms the liquid junction with the external test solution. Dipping into the filling solution is a silver wire coated with a layer of silver chloride (it is chloridised) which is joined to a low-noise cable which connects to the measuring system.

In electrochemical terms, the half-cell can be represented by:

Ag / AgCl (Satd), KCL (Satd)

and the electrode reaction is:

AgCl (s) + e- = Ag (s) + Cl-

The electrode potential for this half-cell is + 0.2046 V relative to the Standard Hydrogen Electrode at 25°C

b) Double Junction Reference Electrodes.

One problem with reference electrodes is that, in order to ensure a stable voltage, it is necessary to maintain a steady flow of electrolyte through the porous frit. Thus there is a gradual contamination of the test solution with electrolyte ions. This can cause problems when trying to measure low levels of K, Cl, or Ag, or when using other ISEs with which these elements may cause interference problems. In order to overcome this difficulty the double junction reference electrode was developed. In this case the silver / silver chloride cell described above forms the inner element and this is inserted into an outer tube containing a different electrolyte which is then in contact with the outer test solution through a second porous frit. The outer filling solution is said to form a "salt bridge" between the inner reference system and the test solution and is chosen so that it does not contaminate the test solution with any ions which would effect the analysis.

Commonly used outer filling solutions are:
potassium nitrate - for Br, Cd, Cl, Cu, CN, I, Pb, Hg, Ag, S, SCN.
sodium chloride - for K,
ammonium sulphate - for N03,
magnesium sulphate - for NH4,
Note that double junction reference electrodes are named after their outer filling solutions.
One disadvantage with double junction reference electrodes is that they introduce an extra interface between two electrolytes and thus give the opportunity for an extra liquid junction potential to develop.

c) Liquid Junction Potentials.
It must be noted that the standard voltage given by a reference electrode is only correct if there is no additional voltage supplied by a liquid junction potential formed at the porous plug between the filling solution and the external test solution. Liquid junction potentials can appear whenever two dissimilar electrolytes come into contact. At this junction, a potential difference will develop as a result of the tendency of the smaller and faster ions to move across the boundary more quickly than those of lower mobility. These potentials are difficult to reproduce, tend to be unstable, and are seldom known with any accuracy; so steps must be taken to minimise them. Using 4 Molar KCL as the inner filling solution has the advantage that the K+ and Cl- ions have nearly equal mobilities and hence form an equi-transferrent solution. Also, in the single junction electrodes, the electrolyte concentration is much higher than that of the sample solution thus ensuring that the major portion of the current is carried by these ions. A third factor in minimising the junction potential is the fact that there is a small but constant flow of electrolyte out from the electrode thus inhibiting any back-diffusion of sample ions - although this is less important with modern gel electrolytes.

As indicated above, all these problems are doubled when double junction reference electrodes are used and an additional problem arises in the case of the last three listed above (Sodium Chloride, Ammonium Sulphate, Magnesium Sulphate) because the filling solutions are not equi-transferrent and hence have a stronger tendency to form liquid junction potentials. It must be noted here that Nico2000 Ltd have recently introduced a novel Lithium Acetate reference electrode which overcomes most of these problems and can be used with all the ELIT range of ISEs. This is because it contains ions which are very nearly equi-tranferrent and which do not interfere with any of the commonly used ISEs.

It must be noted that the E0 factor in the Nernst equation is the sum of all the liquid junction potentials present in the system and any variation in this during analyses can be a major source of potential drift and error in measurements.

d) Combination Electrodes
The majority of pH electrodes are produced in the form of combination electrodes in which the reference system is housed in the same cylindrical body as the sensor head. This produces a simple, compact unit for immersing in the test solution and has the added advantage that the two cells are in close proximity (with the reference cell normally completely surrounding the sensor element) - thus minimising the effect of any stray electrostatic fields or any inhomogeneity in the test solution. The main disadvantage of this arrangement is the fact that it is the reference element which is the most likely to cause problems or fail, long before the ISE head does, but the whole unit has to be replaced when failure does occur.

In contrast to pH electrodes, some ISEs are produced as mono-electrodes for use with separate reference systems. One reason for this is because ISE membranes have a far lower impedance than pH sensors and are less susceptible to stray electrostatic fields. Thus it is not necessary to screen the sensor head by surrounding it with the reference system. More importantly, the membranes and internal construction of ISEs are generally far more expensive than pH sensors and it is much more cost-effective to have separate units in which the reference system can be replaced independently from the ISE.

e) Multiple Electrode Heads: Separable Combinations.

A new concept for combination electrodes has recently been introduced. Both the ISEs and the reference electrodes are made in the form of 8mm diameter tubes fitted with a gold plated plug-in connector. These can be inserted separately into special multiple electrode heads which are fitted with the cables and connectors for attaching to the measuring system. The rigid plastic head ensures that the ISE and reference system remain firmly linked together at a regular distance apart during operation, but either one can easily be replaced in the event of failure or need to change the analysis. Moreover, the replacement electrodes are relatively inexpensive compared to conventional electrodes because they do not incorporate the expensive low-noise cables.

Thursday, December 23, 2010

Projects For You : Pyroelectric Fire Alarm

PYROELECTRIC FIRE ALARM 
By D. Mohan Kumar [Electronics For you]


Here is an ultra-sensitive fire sensor that exploits the direct piezoelectric property of an ordinary piezo element to detect fire. The lead zirconate titanate crystals in the piezo element have the property to deform and generate an electric gate protected p-channel MOSFETs in the inputs. It has high speed of performance and low input current requirements.

There are two inputs—the non-inverting input (pin 3) connected to the piezo element through diode D7 (OA71) that carries the voltage signal from the piezo element and the inverting input (pin 2) that gets a preset voltage momentarily changes the voltage level at pin 3 of IC1 and its output swings high. Transistor T1 conducts taking the reset pin 12 of IC2 to ground. IC2 is now enabled and starts oscillating. With the shown values of the oscillating components C3 (0.22μ) and R6 potential when heated, thus converting the piezo element into a heat sensor.

The circuit described here is very sensitive. It gives a warning alarm if the room temperature increases more\ than 10°C. The entire circuit has two sections—the sensor and the power supply section.

Sensor side circuit. Fig. 1 shows the fire sensor circuit. The front end of the circuit has a sensitive signal amplifier built around IC1 (CA3130). It gives a high output when temperature near the piezo element increases. IC CA3130 is a CMOS operational amplifier with voltage through VR1. By adjusting VR1, it is easy to set the reference voltage level at pin 2. 

In normal condition, IC1 gives a low output and the remaining circuitry is in a standby state. Capacitor C2 keeps the non-inverting input of IC1 stable, so that even a slight change in voltage level in the inputs can change the output to high.

Normally, IC1 gives a low output, keeping transistor T1 non-conducting. Reseting pin 12 of IC2 (CD4060) connected to the collector of transistor T1 gets a high voltage through R5 and IC2 remains disabled. When the piezo element gets heat from fire, asymmetry in its crystals causes a potential change, enabling capacitor C2 to discharge. 

It (1M), the first output (Q3) turns high after a few seconds and a red LED2 starts flashing. If heat near the piezo persists, Q7 (pin 14) output of IC2 becomes high after one minute, and the alarm starts beeping. If heat continues, Q9 (pin 15) turns high after four minutes and turns on the relay driver transistor T2. At the same time, diode D8 conducts and IC2 stops oscillating and toggles.

The solenoid pump connected to the N/O (normally opened) contact of the relay starts spraying the fire-ceasing foam or water to the possible sites of fire. 

Power supply circuit. Power supply section (Fig. 2) comprises a 0-12V, 1A step-down transformer with a standard full-wave rectifier formed by D1 through D4 and filter capacitor C1. A battery backup is provided if the mains supply is cut-off due to short-circuit and fire. A 12V, 4.5Ah rechargeable battery is used for backup to give sufficient current to the solenoid pump. 

When mains power is available, diode D5 forward biases. It provides power to the circuit and also charges the battery through resistor R2, and it limits the charging current to 120 mA. When power fails, diode D5 reverse biases and diode D6 forward biases, giving instant backup to the circuit. LED1 indicates the availability of mains power.

Assemble the circuit on a general purpose PCB and enclose it in a suitable case. Connect the piezo element to the circuit using a thin insulated wire. Glue the flat side of the piezo elto the circuit. LED1 indicates the availability of mains power.

Assemble the circuit on a general purpose PCB and enclose it in a suitable case. Connect the piezo element to the circuit using a thin insulated wire. Glue the flat side of the piezo element on a 30×30cm aluminium sheet to increase its sensitivity. Fix the sheet with the piezo sensor to the site where protection is needed. The remaining circuit can be fixed at a suitable place. If only the alarm generator is needed, omit the relay driver section.

Fig. 1: Pyroelectric fire sensor Figure 2: Power Supply



Wednesday, June 9, 2010

Lasers in Angioplasty/Angiography

Laser Angioplasty


Angioplasty
Angioplasty is used to widen arteries, which are narrowed by stenoses or occlusions. This procedure is helpful in many ways, like, clearing of plaque from coronary arteries, emergency relief from a heart attack that is in progress, and widening narrowed arteries in limbs, such as the femoral or iliac artery to the leg. It is also useful in relieving chest pain, caused by narrowing down of coronary arteries. Angioplasty performed earlier was done by dilating the blood vessel with the introduction of larger stiff catheters, through the narrowed space. However, complications involved in this procedure gave motive to scientists and researchers, to develop a means of widening the vessel using a minimally sized device. Now lasers may be used to assist in the break up of fat or calcium plaque and catheters may also be equipped with spinning wires or drill tips to clean out the plaque.

Laser Angioplasty
In the laser angioplasty technique, a thin and flexible plastic tube called a catheter, with a laser at its tip, is used. It is inserted into an artery that opens into coronary arteries blocked by plaque, a build-up of cholesterol, cells and other fatty substances in an artery's inner lining. Then the plastic tube is advanced through the artery to the blockage in the coronary artery, and it emits pulsating beams of light from where the laser is in position. These lasers help in vaporizing the plaque. The laser technology can be used alone, or in combination with balloon angioplasty. If used along with balloon angioplasty, the balloon is inserted first to attack the hard plaque.

In laser angioplasty mostly eximer laser is used.

Eximer Laser

An excimer laser (sometimes, and more correctly, called an exciplex laser) is a form of ultraviolet laser which is commonly used in angioplasty, eye surgery and semiconductor manufacturing.

The term excimer is short for 'excited dimer', while exciplex is short for 'excited complex'. An excimer laser typically uses a combination of an inert gas (argon, krypton, or xenon) and a reactive gas (fluorine or chlorine).

Under the appropriate conditions of electrical stimulation, a pseudo-molecule called an excimer (or in case of noble gas halides, exciplex) is created, which can only exist in an energized state and can give rise to laser light in the ultraviolet range.